Fragility curves based on the numerical analysis of masonry walls against subsidence, using the Abaqus / CAE software and relying on the pulldown technique

Yaimara Chávez-Pérez1, José A. Ortiz-Lozano1*

1Centro de Ciencias del Diseño y de la Construcción, Universidad Autónoma de Aguascalientes, Edificio 108, Aguascalientes, México

A B S T R A C T

This research uses Abaqus / CAE software as a computational tool, to obtain numerical models that correctly describe the behavior of masonry walls against subsidence. To do this, a mathematical calibration process is performed, the angular distortion values ​​are obtained for different load states and compared with the experimental results presented by the researcher Charry Ablanque in 2010, the influence of the dimensions of the wall is studied in its resistance and the fragility curves of the material are constructed to evaluate the state of damage of the element, for a certain value of angular distortion.

2 Methodology

Numerical methodology:

Use micro-modeling to obtain and determine a numerical model capable of reproducing the real behavior of a masonry wall under the effect of the pushover.

Compare the experimental results obtained by Daniel Charry Ablanque in 2010, as part of his PhD thesis, with the numerical results to calibrate the model.

From the calibrated model the wall will be subjected to the pulldown effect (vertical load) in order to simulate the effect of the differential settlements in the structure and obtain the angular distortion values ​​for the different load values.

Construct the fragility curves of the material, by means of which a probabilistic analysis of the behavior of the wall will be carried out, establishing the probability that the structural response of the same exceeds a certain limit state, as a function of the angular distortion.

Analyze the results to assess the damage status of a masonry structure, depending on the value of the angular distortion to which it is subjected.

2.1 Calibration of the numerical model.

The calibration process took into account the geometrical characteristics and properties of the materials used by Charry Ablanque in his experimental campaigns I and III. The percentage difference or relative error between the numerical and experimental models corresponds to the following expression:

Failed to parse (syntax error): {\textstyle Dif\, \%=\, \frac{⎪{U}_{e\, \left( i\right) }-{U}_{m\, \left( i\right) \, }⎢}{{U}_{m\, \left( i\right) \, }}}
[8]


Draft Chavez Perez 889564093-picture-1 Cuadro de texto.svg

Where:

Ue (i): displacement corresponding to the load (i) in the experimental test.

Um (i): displacement corresponding to the same load in mathematical modeling.

'2.1.1' Calibration experimental campaign I.

Charry during his first experimental campaign, analyzed 10 walls of 1.20 m x 1.0 m, subjected to 10 different loading states. The specimens were composed of 16 rows of solid brick of 290 x 140 x 50 mm, whose coefficient of friction, cohesion, and compressive strength correspond to the values ​​of 45 o, 0.32 MPa and 11.6 MPa, respectively.

For the calibration, the maximum vertical load value considered was 150 kN and 80 kN of horizontal load, which caused two types of faults in the wall (tensile fracture of the bricks and sliding of the joints) (See figure 1).

Draft Chavez Perez 889564093-image1-c.png

Draft Chavez Perez 889564093-image2-c.png

The percentage difference calculated between the numerical model and the experimental model was 13.57%, considering displacements of 31.24 mm in the numerical model and 27 mm in the experimental model (See graphic 1).

Draft Chavez Perez 889564093-chart1.svg
Graph 1:Load displacement curve for the 150V80H wall.

2.1.2 Experimental campaign calibration III

The third experimental campaign was carried out on walls on a reduced scale with dimensions of 300 x 250 x 35 mm. In total, 15 walls were tested, whose mechanical properties were obtained during the development of the experiments, resulting in a cohesion, a coefficient of friction and a compressive strength of 0.46 MPa, 33.42 o and 10.65 MPa respectively.

For the calibration, the maximum vertical load value considered was 9 kN and 5 kN of horizontal load, which caused sliding in the joints of the wall (See Figure 2). The

percentage difference between the numerical model and the experimental it was 12.39%, for maximum values ​​of displacements of 0.114 mm in the numerical model and 0.1 mm in the experimental one (See graphic 2).

Draft Chavez Perez 889564093-image3.png

Draft Chavez Perez 889564093-image4-c.png
Draft Chavez Perez 889564093-picture-3 Cuadro de texto.svg
Draft Chavez Perez 889564093-chart2.svg
Graph 2: Load displacement curve for the 9V5H wall.

2.2 Experiment design.

In the second stage of the investigation, the subsidence numerical models are analyzed, which were considered isolated, unconfined and not reinforced walls, composed of solid pieces of red partition of 29 x 14 x 7 cm and mortar joints of 1 cm, whose dimensions vary between the experimental campaign I and the experimental campaign II.

Experimental campaign I

Isolated wall, not confined and not reinforced, 1 m x 1 m, subjected to vertical loads of presión of 270 kN / m2 and 300 KN / m2, in the middle of its base.

Experimental campaign II

Isolated, unconfined and non-reinforced walls of 1 m x 1 m, 1.5 m x 1.5 m and 2 m x 2 m, subjected to a vertical pressure load of 500 KN / m2, in the middle of its base.

2.2.1 Materials.

Partitions

The behavior of the partitions was reproduced through the Mohr-Coulomb constitutive model, whose basic parameters hey are the coefficient of friction, the cohesion and the angle of dilatation.

A coefficient of friction of 35o, a cohesion of 0.4 MPa and a dilatancy angle of 0 was considered, following the recommendations of E. Dumova-Jovanoska & S. Churilov for clay partitions.

In addition to the Mohr-Coulomb constitutive model, the density of the materials (Υ) and an elastic model defined by the Young's modulus (E) and the Poisson's coefficient (ν) were taken into account (See table 1).

Density

(kN/m3)

Young's module

(kN/m2)

Poisson's coefficient
13 4,170,000 0.15


Table 1: Summary of the properties of the partitions.

Mortar

The simulation of the behavior of the mortar was made through the Drucker-Prager plastic damage model.

This constitutive model requires five basic input parameters, the internal friction angle, the angle of expansion, the range of stresses that cause plastic deformation, the yield stress and the absolute plastic deformation, in addition to the Young's modulus (E), the Poisson's coefficient (ν) and the density (Υ) of the material.

The angle of friction and the angle of dilatation, according to what was proposed by Oller in 2001, are considered equal to zero for concretes that do not present damages and take their maximum value (Ф = 36 ° and ψ = 15 °) when

This is defective. In this case, a mortar without structural damage is considered, so the angle of friction and the angle of dilatation are considered equal to 0.

"The range of stresses that cause plastic deformation (kp) varies between zero and one; for kp = 0 there is no damage to the material and for kp = 1 the plastic damage is established in its entirety "[3]. In numerical modeling, the range of stresses that causes plastic deformation equal to 0.8 is established.

The plastic yield stress depends on the compressive strength of the mortar, for a resistance of 8 MPa, the tension is considered 4 MPa [9].

The modulus of elasticity was considered to be 4,170,000 kN / m2, the Poisson's coefficient of 0.2 and the mortar density of 20 kN / m3.

2.2.2 Interactions.

The piece-mortar interaction is defined as a surface to surface contact, considering the elastic and inelastic parameters of the joints.

Elastic parameters

Oliveira in 2003 uses several analytical criteria to determine the rigidity parameters of the mortar-brick joints, determining that these depend fundamentally on the vertical precompression load. In this case, the normal stiffness was considered equal to 420.3 N / mm3 and the tangential rigidity equal to 195.49 N / mm3, recommended values ​​for loads greater than 250 kN.

Inelastic parameters

The inelastic parameters of the boards were obtained from the research carried out by Álvaro Viviescas in 2009 (See table 2).

Tension Cutting
ft (MPa) G´f (MPa) c (MPa) G´´f (MPa)
0.55 0.13 0.4 0.045


Table 2: Inelastic parameters of the contact joints between units.

2.2.3 Meshing.

"The number of nodes gives finite second-order elements greater precision in mathematical analysis, but they make it difficult to converge in complex nonlinearity problems" [10], which is why a finite element of the first order was used. type C3D8 and a mesh density of 5 cm (See graph 3).

Draft Chavez Perez 889564093-chart3.svg

Graph 3: Curve number of nodes vs settlement.

3 Results

At the end of the calibration process, a vertical load was applied in the middle of the base of the walls and the other half was embedded, to simulate the effects of differential land subsidence. These numerical models were analyzed in two experimental campaigns.

Experimental campaign I

The experimental campaign I considered two walls of 1 mx 1 m with different load values ​​applied in the middle of its base, observing the areas where the highest stresses accumulate (See Figure 3) and measuring the values ​​of angular distortion, until reaching the failure of the element (See graphs 4 and 5)


Draft Chavez Perez 889564093-image5-c.png


Draft Chavez Perez 889564093-image6-c.png
Draft Chavez Perez 889564093-picture-4 Cuadro de texto.svg

Draft Chavez Perez 889564093-chart4.svg
Graph 4: Angular distortion stress curve for a pressure of 250 kN / m2.

Draft Chavez Perez 889564093-chart5.svg

Graph 5: Angular distortion stress curve for a pressure of 300 kN / m2.

Experimental campaign II

In experimental campaign II, three walls were modeled with variable dimensions (1 m x 1 m, 1.5 m x 1.5 m and 2 m x 2 m), considering the same load value, applied to half of its base. In the simulation, the zones where the highest stresses are concentrated were analyzed (See figures 4, 5 and 6) and the angular distortion values ​​were obtained (See graphs 6 and 7)


Draft Chavez Perez 889564093-image6-c1.png
Figure 4: Wall of 1 m x 1 m, load
500 kN / m2.


Draft Chavez Perez 889564093-image7-c.png

Draft Chavez Perez 889564093-picture-295 Cuadro de texto.svg
Figure 5: 1.5 m x 1.5 m wall, load 500 kN / m2.

Draft Chavez Perez 889564093-chart6.svg

Graph 6: Angular distortion stress curve for a pressure of 500 kN / m2 (Wall of 1 m x 1 m).
Draft Chavez Perez 889564093-chart7.svg

Draft Chavez Perez 889564093-image8-c.png
Graph 7: Angular distortion stress curve for a pressure of 500 kN / m2 (Walls of 1.5 m x 1.5 m and 2 m x 2 m).

4 Discussion of results

Draft Chavez Perez 889564093-image9-c.png

The numerical results were compared with the experimental tests developed by Daniel Lara, concluding that in both cases the tensions begin at the base of the wall and extend towards the sides with an inclination of approximately 45 o (See figures 7 and 8).


Draft Chavez Perez 889564093-picture-7 Cuadro de texto.svg

Draft Chavez Perez 889564093-picture-8 Cuadro de texto.svg

Draft Chavez Perez 889564093-image6-c2.png

When the angular distortions reach a value of approximately 0.04, the material begins to have a plastic behavior, reaching its failure. East valor concuerda con el propuesto por Meli in 2014, to evaluate the state of damage of a masonry wall, as opposed to differential settlements.

Experimental campaign I

The angular distortion stress curves in the wall of 1 mx 1 m, show a greater ductility for lower load conditions, presenting angular distortions greater than 0.03, with smaller stresses and even without reaching the wall failure (See graphic 8) .

Draft Chavez Perez 889564093-chart8.svg
Graph 8: Curve effort angular distortion.

The difference in the behavior of the wall, is mainly due to the state of efforts to which it is subjected in its initial stage, which agrees with what was stated by Meli in 2014, where it states that the initial effort state defines the type of failure to be presented.

Experimental campaign II

During the second experimental campaign, the behavior of 1.5 m x 1.5 m and 2 m x 2 m walls was analyzed, which were subjected to the same load value, applied in its base, to simulate a differential settlement.

The 2 m x 2 m wall shows lower values ​​of angular distortion than the 1.5 m x 1.5 m wall, for similar load values, although in both it agrees that the element failure occurs for a distortion value of approximately 0.04. The which shows that by increasing the dimensions of the wall (maintaining the width / length ratio equal to 1), its resistance

before differential settlements, needing greater efforts to reach their failure.

4.1 Fragility curves.

Fragility curves establish a measure of vulnerability, in probabilistic terms, of the behavior of a given system [2]. These depend on the density function discussed earlier in the introduction.

Walls of 1 m x 1 m

The three walls of 1 mx 1 m subjected to differential subsidence, were used to construct the first fragility curves, taking into account the values ​​of angular distortion, corresponding to light, moderate and severe damage and calculating their natural logarithm, mean and standard deviation (See table 3) (See graph 9).

The walls of 1.5 mx 1.5 m and 2 mx 2 m subjected to differential subsidence, were used to construct the second fragility curves, taking into account the values ​​of angular distortion, corresponding to slight, moderate and severe damage and calculating their natural logarithm, average and standard deviation (See table 4) (See figure 10).

Experimental campaign I Angular distortion in % Ln of angular distortion in %
0,5 Tension

maximum

0,65 Tension

maximum

Tension

maximum

0,5 Tension

maximum

0,65 Tension

maximum

Tension

maximum

1 m x 1 m P=250kN/m2 1 1,8 6 -4,605 -4,017 -2,813
1 m x 1 m P=300kN/m2 1,2 2 5 -3,507 -3,912 -2,996
1 m x 1 m P=350kN/m2 1,4 1,89 6 -4,605 -3,969 -2,813
Half 0,0120 0,0190 0,0567 -4,2390 -3,9660 -2,8740
Standard deviation 0,00943 0,000818 0,00471 0,518 0,0429 0,086


Table 3: Distortion associated to each level of damage. Natural logarithm, mean and standard deviation for obtaining the fragility curves.
Draft Chavez Perez 889564093-chart9.svg
Graph 9: Fragility curves obtained for a 1 m x 1 m wall (Experimental Campaign I).
Experimental campaign II Angular distortion in  % Ln of angular distortion in %
0,5 Tension

maximum

0,65 Tension

maximum

Tension

maximum

0,5 Tension

maximum

0,65 Tension

maximum

Tension

maximum

1 m x 1 m P=350kN/m2 1.4 1.89 6 -4.269 -3.969 -2.813
1.5 m x 1.5 m P=350kN/m2 1.9 1.98 5.2 -3.963 -3.922 -2.957
2 m x 2 m P=350kN/m2 0.7 1.0 4.0 -4.962 -4.605 -3.219
Half 0.0133 0.0162 0.051 -4.398 -4.165 -2.996
Standard deviation 0.00492 0.00442 0.00822 0.418 0.311 0.168


Table 4: Distortion associated to each level of damage (Walls of 1 m x 1 m, 1.5 m x 1.5 m and 2 m x 2 m). Natural logarithm, mean and standard deviation for obtaining the fragility curves.
Draft Chavez Perez 889564093-chart10.svg
Graph 10: Fragility curves obtained for a wall of 1 m x 1 m, 1.5 m x 1.5 m and 2 m x 2 m (Experimental Campaign II).

4 Conclusions

The main objective of this research is to evaluate the behavior of masonry walls against subsidence, using the fragility curves. All the numerical process by which it was transited to obtain the expected results, throw the following conclusions:

1- The computational modeling using the software Abaqus / CAE, based on the Finite Element Method, is a very accurate tool for the analysis of masonry walls against subsidence. What allowed to obtain a calibrated numerical model and the values ​​of angular distortion for walls of 1.0mx1.0m, 1.5mx1.5m and 2.0mx2.0m.

2- The cracks in the walls caused by the subsidence begin at the base and extend towards the sides with a slope of approximately 45 o.

3- In the angular distortions it is observed that when reaching a value of approximately 0.04, the material begins to have a plastic behavior, reaching its failure. This value agrees with that proposed by Meli in 2014, to evaluate the damage status of a masonry wall, as opposed to differential settlements.

4- The curves of effort angular distortion in the wall of 1mx1m, show a greater ductility for lower load conditions, to present angular distortions greater than 0.03, with smaller efforts and even without reaching the wall failure.

5- The 2mx2m wall shows lower values ​​of angular distortion than the 1.5mx1.5m wall, for similar load values, although in both it agrees that the element failure occurs for a distortion value of approximately 0.04. Which shows that by increasing the dimensions of the wall (maintaining the width / length ratio equal to 1), its resistance to differential settlements grows, requiring greater efforts to reach its failure.

6- Fragility curves are a very useful tool to assess the damage status of a masonry wall.

5 References

1. Jesús, P.M. and A.F. Jorge, Análisis multicapa, de la subsidencia en el valle Querétaro, México, in Revista Mexicana de Ciencias Geológicas. 2007: México. p. 389 a 402.

2. Luis, H.-C., et al., Fragility curves for thin-walled cold - formed steel wall frames affected  by ground settlements due to land subsidence  in Thin-WalledStructures. 2014: Aguascalientes, México.

3. Oller, S., Mecánica de la fractura.  Enfoque global, ed. P. Edición. 2001.

4. Ramos, R.F.J., Simulación numérica y experimental de estructuras de acero rolado en frío por hundimientos diferenciales asociados al fenómeno de la subsidencia. 2013, Universidad Autónoma de Aguascalientes: Aguascalientes, México.

5. Roberto, T., et al., Subsidencia del terreno.  Ground subsidence  2009.

6. J., L., O. S., and O. E., Cálculo del comportamiento de la mampostería mediante elementos finitos. 1ra edición ed. 1998, Barcelona, España.

7. Ruiz, G. Jorge, and N. Miguel, Drift-based fragility assessment of confined masonry walls in seismic zones. Engineering Structures, 2009.

8. C.a, T., Comparison of non linear elastic and electroplating models., ed. A.P.N. 94-1076. 1994.

9. P. Kmiecik, M.K., Modelling of reinforced concrete structures and composite structures with concrete strength degradation taken into consideration. 2011.

10. Quintero, J.C., Validación de métodos gráficos para determinar la capacidad de carga a partir de resultados de la modelación matemática, in Departamento de Ingeniería Civil  2013, Instituto Superior Politécnico ¨José Antonio Echeverría¨: La Habana.

Back to Top

Document information

Published on 22/01/20
Accepted on 12/11/19
Submitted on 11/10/18

Volume 36, Issue 1, 2020
DOI: 10.23967/j.rimni.2019.11.002
Licence: CC BY-NC-SA license

Document Score

0

Views 254
Recommendations 0

Share this document

claim authorship

Are you one of the authors of this document?