Abstract

n extensive, detailed survey of users of high density polyethylene (HDPE) water pipe in the United States and Europe, as well of manufacturers of appropriate products, has been conducted to determine the practicality and effectiveness of inservice field repairs of the HDPE pipe, including both fusion and non-fusion techniques. As a result of the study, commercially available mechanical (non-fusion) repair fittings and methods that have been successfully employed have been identified, based on their relative convenience and reliability. The present study focused on water distribution pipelines and force mains of sizes 2-in. through 16-in.


Original document

The different versions of the original document can be found in:

http://dx.doi.org/10.1061/9780784413692.115
https://ascelibrary.org/doi/pdf/10.1061/9780784413692.115,
https://academic.microsoft.com/#/detail/2145160941
Back to Top

Document information

Published on 01/01/2014

Volume 2014, 2014
DOI: 10.1061/9780784413692.115
Licence: CC BY-NC-SA license