Abstract

The stress analysis is presented for the proposed loop seal modification to the LOFT Steam Generator Main Feed Piping. THE SAP IV finite element computer program was used to analyze normal, upset, emergency, and faulted conditions. Results of the analysis indicate that the modified main feed piping system will satisfy all structural adequacy criteria specified in Subarticle NC-3650 of the ASME Boiler and Pressure Vessel Code. Results also show that the isolation snubber configuration, specified in LTR 115-11, will also be adequate for the piping configuration analyzed.