Abstract

Test results of sludge slurry transport through the Interarea Transfer Line (IAL) Mock-up Facility showed little risk of plugging the interarea pipelines with sludge slurry. Plug-free operation of the pipeline was successfully demonstrated by worst case IAL operating scenarios. Pipeline pressure gradients were measured vs. flow rate for comparison with a computer model over a range of sludge slurry rheological properties. A mathematical computer model developed by L. M. Lee is included in this report which will predict pressure drop for Bingham plastic fluid flow in a pipeline. IAL pluggage situations and pumping requirements may be realized from this model. 4 refs., 11 figs., 2 tabs.


Original document

The different versions of the original document can be found in:

https://academic.microsoft.com/#/detail/25832650
Back to Top

Document information

Published on 01/01/1987

Volume 1987, 1987
DOI: 10.2172/6462326
Licence: CC BY-NC-SA license

Document Score

0

Views 2
Recommendations 0

Share this document

claim authorship

Are you one of the authors of this document?