(Created page with " == Abstract == A preliminary study of the feasibility of using existing drinking water supply systems to provide hot water for heating purposes to a typical 140-home subdivi...")
 
 
(2 intermediate revisions by the same user not shown)
Line 2: Line 2:
 
== Abstract ==
 
== Abstract ==
  
A preliminary study of the feasibility of using existing drinking water supply systems to provide hot water for heating purposes to a typical 140-home subdivision has been undertaken. This preliminary study has centered on (i) types of municipal water system designs and effects of system design upon heating use; (ii) methods of using low-to-moderate temperature water for heating purposes and possible institutional barriers; (iii) identification and description of a typical residential community suitable for hot water heating; (iv) evaluation of thermal losses in the uninsulated main distribution system from the main pumping station having assumed geothermal heating to the subdivision; (v) evaluation of thermal losses in the uninsulated street mains in the subdivision; (vi) estimation of size and cost of the pumping station main heat exchanger to supply geothermal energy to the drinking water; (vii) sizing of individual house heat exchangers; (viii) pumping and power requirements to supply the increased water flow rate through the subdivision street water distribution lines; and (ix) pumping and piping requirements to provide heating water flow from the street lines to a typical residence. From the results obtained thus far, it would appear that the use of existing uninsulated water supply systems will be advantageous more » in many communities having nearby low-to-moderate temperature geothermal resources. « le
+
preliminary study of the feasibility of using existing drinking water supply systems to provide hot water for heating purposes to a typical 140-home subdivision has been undertaken. This preliminary study has centered on (i) types of municipal water system designs and effects of system design upon heating use; (ii) methods of using low-to-moderate temperature water for heating purposes and possible institutional barriers; (iii) identification and description of a typical residential community suitable for hot water heating; (iv) evaluation of thermal losses in the uninsulated main distribution system from the main pumping station having assumed geothermal heating to the subdivision; (v) evaluation of thermal losses in the uninsulated street mains in the subdivision; (vi) estimation of size and cost of the pumping station main heat exchanger to supply geothermal energy to the drinking water; (vii) sizing of individual house heat exchangers; (viii) pumping and power requirements to supply the increased water flow rate through the subdivision street water distribution lines; and (ix) pumping and piping requirements to provide heating water flow from the street lines to a typical residence. From the results obtained thus far, it would appear that the use of existing uninsulated water supply systems will be advantageous more » in many communities having nearby low-to-moderate temperature geothermal resources. « le
 
+
Document type: Report
+
 
+
== Full document ==
+
<pdf>Media:Draft_Content_751489993-beopen123-8113-document.pdf</pdf>
+
  
  
Line 18: Line 13:
 
* [https://digital.library.unt.edu/ark:/67531/metadc1101687/m2/1/high_res_d/5905644.pdf https://digital.library.unt.edu/ark:/67531/metadc1101687/m2/1/high_res_d/5905644.pdf]
 
* [https://digital.library.unt.edu/ark:/67531/metadc1101687/m2/1/high_res_d/5905644.pdf https://digital.library.unt.edu/ark:/67531/metadc1101687/m2/1/high_res_d/5905644.pdf]
  
* [https://www.osti.gov/scitech/servlets/purl/5905644 https://www.osti.gov/scitech/servlets/purl/5905644],[https://academic.microsoft.com/#/detail/1980462798 https://academic.microsoft.com/#/detail/1980462798]
+
* [https://www.osti.gov/servlets/purl/5905644 https://www.osti.gov/servlets/purl/5905644],
 +
: [https://academic.microsoft.com/#/detail/1980462798 https://academic.microsoft.com/#/detail/1980462798]

Latest revision as of 18:05, 25 January 2021

Abstract

preliminary study of the feasibility of using existing drinking water supply systems to provide hot water for heating purposes to a typical 140-home subdivision has been undertaken. This preliminary study has centered on (i) types of municipal water system designs and effects of system design upon heating use; (ii) methods of using low-to-moderate temperature water for heating purposes and possible institutional barriers; (iii) identification and description of a typical residential community suitable for hot water heating; (iv) evaluation of thermal losses in the uninsulated main distribution system from the main pumping station having assumed geothermal heating to the subdivision; (v) evaluation of thermal losses in the uninsulated street mains in the subdivision; (vi) estimation of size and cost of the pumping station main heat exchanger to supply geothermal energy to the drinking water; (vii) sizing of individual house heat exchangers; (viii) pumping and power requirements to supply the increased water flow rate through the subdivision street water distribution lines; and (ix) pumping and piping requirements to provide heating water flow from the street lines to a typical residence. From the results obtained thus far, it would appear that the use of existing uninsulated water supply systems will be advantageous more » in many communities having nearby low-to-moderate temperature geothermal resources. « le


Original document

The different versions of the original document can be found in:

https://academic.microsoft.com/#/detail/1980462798
Back to Top

Document information

Published on 01/01/1979

Volume 1979, 1979
DOI: 10.2172/5905644
Licence: CC BY-NC-SA license

Document Score

0

Views 0
Recommendations 0

Share this document

claim authorship

Are you one of the authors of this document?