J. González, A. Vazquez, G. Jauregui, C. Andrade
In the present work is described the effect of the characteristics of the galvanized coating on corrosion rate of reinforcing bars embedded in a concrete without additives and in another with 2% CaCl2 in terms of cement weight. To this end, the following materials were subjected to the action of a moisture saturated atmosphere for a period of400 days: an annealed-galvanized coating; another one obtained by dipping in a molten Zn bath with0.025% Al and some others produced at450 and430°C in an ordinary bath.
The attack evolution vs time was controlled by measuring the polarization resistance. The electrochemical determinations were gravimetrically verified and supplemented by a metallographic examination of tests coatings.
In the absence of chlorides, the attack is fully tolerated. Chlorides radically change the corrosion behaviour of galvanized steel and increase the attack by a factor of2.8 in the most favourable case, but in these conditions, coatings with thick, homogeneous η layer outperform the usual ones, and specially the annealed ones.
Published on 01/01/1984
DOI: 10.1007/BF02473980Licence: CC BY-NC-SA license
Views 2Recommendations 0
Are you one of the authors of this document?