(2.3 Lateral hydrodynamic pressures)
(References)
 
(26 intermediate revisions by the same user not shown)
Line 46: Line 46:
 
The seismic response of liquid-containing tanks has been also studied with numerical procedures. The main numerical methods include finite elements, boundary elements or finite differences. For example, Zhao ''et al''. [20] used the boundary-element method (BEM) to study the nonlinear sloshing in rectangular tanks under base excitations. In their study, the hydrodynamic pressures were validated with experimental tests. Ning ''et al''. [21] also used the BEM to study sloshing of liquids in tanks subjected to both horizontal and vertical excitations. Hu ''et al''. [22] studied the natural frequencies of 2D tanks using the BEM.
 
The seismic response of liquid-containing tanks has been also studied with numerical procedures. The main numerical methods include finite elements, boundary elements or finite differences. For example, Zhao ''et al''. [20] used the boundary-element method (BEM) to study the nonlinear sloshing in rectangular tanks under base excitations. In their study, the hydrodynamic pressures were validated with experimental tests. Ning ''et al''. [21] also used the BEM to study sloshing of liquids in tanks subjected to both horizontal and vertical excitations. Hu ''et al''. [22] studied the natural frequencies of 2D tanks using the BEM.
  
The finite-element method (FEM) has also been used to study tanks subjected to ground motions. For instance, Hwang and Ting [23] combined the BEM and the FEM to study the dynamic response of liquid storage tanks subjected to earthquake ground motions. Taylor ''et al''. [24] also combined both finite and boundary elements to model the interaction of nonlinear waves in tanks. Wu ''et al''. [25] analyzed the sloshing waves in 3D tank using the FEM. Aslam [26] also studied sloshing in cylindrical tanks induced by ground motions. Babu and Bhattacharyya [27] studied the fluid-structure interaction effect on liquid-retaining structures due to sloshing using finite element analysis. Other studies using the FEM include references [28- 29].
+
The finite-element method (FEM) has also been used to study tanks subjected to ground motions. For instance, Hwang and Ting [23] combined the BEM and the FEM to study the dynamic response of liquid storage tanks subjected to earthquake ground motions. Taylor ''et al''. [24] also combined both finite and boundary elements to model the interaction of nonlinear waves in tanks. Wu ''et al''. [25] analyzed the sloshing waves in 3D tank using the FEM. Aslam [26] also studied sloshing in cylindrical tanks induced by ground motions. Babu and Bhattacharyya [27] studied the fluid-structure interaction effect on liquid-retaining structures due to sloshing using finite element analysis. Other studies using the FEM include Arafa [28] and Cho and Lee [29].
  
 
The finite-difference method (FDM) has been used, for instance, by Chen ''et al''. [6], by Hernandez ''et al''. [30] and by Frandsen and Bortwick [31] to study the nonlinear sloshing of a liquid contained in cylindrical and rectangular tanks subjected to ground motions.
 
The finite-difference method (FDM) has been used, for instance, by Chen ''et al''. [6], by Hernandez ''et al''. [30] and by Frandsen and Bortwick [31] to study the nonlinear sloshing of a liquid contained in cylindrical and rectangular tanks subjected to ground motions.
Line 93: Line 93:
 
|}
 
|}
  
where <math display="inline"> \omega </math> is the liquid circular frequency and <math display="inline">t</math> is the time. These fields lead to maximum fluid horizontal displacement at the bottom for <math display="inline">x= 0</math> and maximum vertical displacement of the liquid of the surface at <math display="inline">x = l</math>. They also lead to <math display="inline">\, {d}_{h} = 0</math>, <math display="inline">{d}_{v}= 0</math> at the tank bottom (<math display="inline">y = h t</math>). The horizontal and vertical velocity fields result. The liquid movement resulting of these displacement fields is illustrated in [[#img-3|Figure 3]]. In these equations <math display="inline">t</math> is the time.
+
where <math display="inline"> \omega </math> is the liquid circular frequency and <math display="inline">t</math> is the time. These fields lead to maximum fluid horizontal displacement at the bottom for <math display="inline">x= 0</math> and maximum vertical displacement of the liquid of the surface at <math display="inline">x = l</math>. They also lead to <math display="inline">\, {d}_{h} = 0</math>, <math display="inline">{d}_{v}= 0</math> at the tank bottom (<math display="inline">y = h</math>). The horizontal and vertical velocity fields result. The liquid movement resulting of these displacement fields is illustrated in [[#img-3|Figure 3]]. In these equations <math display="inline">t</math> is the time.
  
In these fields, the variable <math display="inline">E</math> is the maximum horizontal displacement of the fluid (Fig. 3). The liquid volume reduction that occurs at one side of the tank when the surface lowers should be equal to the volume increment at the other side of the tank ([[#img-3|Figure 3]]). Therefore the maximum horizontal displacement (<math display="inline">E</math>) can be expressed in terms of the maximum vertical displacement (<math display="inline">D</math>):
+
<div id='img-3'></div>
 +
{| style="text-align: center; border: 1px solid #BBB; margin: 1em auto; width: auto;max-width: auto;"
 +
|-
 +
|style="padding:10px;"|  [[Image:Draft_De-la-Colina_143057818-image3.png|276px]]
 +
|- style="text-align: center; font-size: 75%;"
 +
| colspan="1" style="padding:10px;"| '''Figure 3'''. Fluid displacement
 +
|}
 +
 
 +
 
 +
In these fields, the variable <math display="inline">E</math> is the maximum horizontal displacement of the fluid ([[#img-3|Figure 3]]). The liquid volume reduction that occurs at one side of the tank when the surface lowers should be equal to the volume increment at the other side of the tank ([[#img-3|Figure 3]]). Therefore the maximum horizontal displacement (<math display="inline">E</math>) can be expressed in terms of the maximum vertical displacement (<math display="inline">D</math>):
  
 
{| class="formulaSCP" style="width: 100%; text-align: center;"  
 
{| class="formulaSCP" style="width: 100%; text-align: center;"  
Line 106: Line 115:
 
| style="width: 5px;text-align: right;white-space: nowrap;" | (3)
 
| style="width: 5px;text-align: right;white-space: nowrap;" | (3)
 
|}
 
|}
 
 
<div id='img-3'></div>
 
{| style="text-align: center; border: 1px solid #BBB; margin: 1em auto; width: auto;max-width: auto;"
 
|-
 
|style="padding:10px;"|  [[Image:Draft_De-la-Colina_143057818-image3.png|276px]]
 
|- style="text-align: center; font-size: 75%;"
 
| colspan="1" style="padding:10px;"| '''Figure 3'''. Fluid displacement
 
|}
 
 
  
 
The velocity fields resulting of these displacement fields are given by the following equations after taking derivatives with respect to the time <math display="inline">t</math>:
 
The velocity fields resulting of these displacement fields are given by the following equations after taking derivatives with respect to the time <math display="inline">t</math>:
Line 264: Line 263:
 
|}
 
|}
  
If the total maximum kinetic energy (Eq. 11) is set equal to the liquid input energy (Eq. 12), an expression for <math display="inline">D</math> can be obtained. This assumes that when the maximum kinetic energy occurs, the potential energy is equal to zero. Thus, the expression to estimate the maximum liquid sloshing height is
+
If the total maximum kinetic energy (Eq. (11)) is set equal to the liquid input energy (Eq. (12)), an expression for <math display="inline">D</math> can be obtained. This assumes that when the maximum kinetic energy occurs, the potential energy is equal to zero. Thus, the expression to estimate the maximum liquid sloshing height is
  
 
{| class="formulaSCP" style="width: 100%; text-align: center;"  
 
{| class="formulaSCP" style="width: 100%; text-align: center;"  
Line 287: Line 286:
 
{| style="text-align: center; margin:auto;"  
 
{| style="text-align: center; margin:auto;"  
 
|-
 
|-
| <math>p\left( x,y\right) =\, -\rho \left[ \frac{\partial \phi }{\partial t}+ \frac{1}{2}\, \nabla \phi \cdot \nabla \phi +x{a}_{x}+gy\right] =</math> <math>\, {p}_{1}+{p}_{2}+{p}_{3}+{p}_{s}=\, {p}_{d}+{p}_{s}</math>
+
| <math>p\left( x,y\right) =\, -\rho \left[ \frac{\partial \phi }{\partial t}+ \frac{1}{2}\, \nabla \phi \cdot \nabla \phi +x{a}_{x}+gy\right] =</math> <math>{p}_{1}+{p}_{2}+{p}_{3}+{p}_{s}=\, {p}_{d}+{p}_{s}</math>
 
|}
 
|}
 
| style="width: 5px;text-align: right;white-space: nowrap;" | (17)
 
| style="width: 5px;text-align: right;white-space: nowrap;" | (17)
 
|}
 
|}
  
where ''&#x03a6;'' is the velocity potential function, <math display="inline">{\, a}_{x}</math> is the ground motion peak acceleration and <math display="inline">g</math> is the gravity acceleration. This equation applies for inviscid, incompressible and irrotational fluids.
+
where <math>\phi </math> is the velocity potential function, <math display="inline">{\, a}_{x}</math> is the ground motion peak acceleration and <math display="inline">g</math> is the gravity acceleration. This equation applies for inviscid, incompressible and irrotational fluids.
  
 
The pressure term <math display="inline">{p}_{1}</math> can be obtained as follows. Taking the partial derivative of this term with respect to <math display="inline">y</math>
 
The pressure term <math display="inline">{p}_{1}</math> can be obtained as follows. Taking the partial derivative of this term with respect to <math display="inline">y</math>
Line 298: Line 297:
 
{| class="formulaSCP" style="width: 100%; text-align: center;"  
 
{| class="formulaSCP" style="width: 100%; text-align: center;"  
 
|-
 
|-
| <math>\frac{\partial {p}_{1}}{\partial y}=\, -\rho \frac{\partial }{\partial y}\left( \frac{\partial \phi }{\partial t}\right) =\, -</math><math>\rho \frac{\partial }{\partial t}\left( \frac{\partial \phi }{\partial y}\right) =\, -</math><math>\rho \frac{\partial }{\partial t}\, v</math>
+
| <math>\frac{\partial {p}_{1}}{\partial y}=\, -\rho \frac{\partial }{\partial y}\left( \frac{\partial \phi }{\partial t}\right) =\, -</math><math>\rho \frac{\partial }{\partial t}\left( \frac{\partial \phi }{\partial y}\right) =-</math><math>\rho \frac{\partial }{\partial t}\, v</math>
 
|}
 
|}
  
Line 307: Line 306:
 
|}
 
|}
  
The maximum vertical acceleration at the wall results (after Eq. 5):
+
The maximum vertical acceleration at the wall results (after Eq. (5)):
  
 
{| class="formulaSCP" style="width: 100%; text-align: center;"  
 
{| class="formulaSCP" style="width: 100%; text-align: center;"  
Line 314: Line 313:
 
{| style="text-align: center; margin:auto;"  
 
{| style="text-align: center; margin:auto;"  
 
|-
 
|-
| <math>\overset{\cdot}{v}=-D{\omega }^{2}\, cos\left( \frac{\pi \, y}{2\, h}\right)</math>
+
| <math>\overset{\cdot}{v}=-D{\omega }^{2}\, \cos\left( \frac{\pi \, y}{2\, h}\right)</math>
 
|}
 
|}
 
| style="width: 5px;text-align: right;white-space: nowrap;" | (18)
 
| style="width: 5px;text-align: right;white-space: nowrap;" | (18)
Line 326: Line 325:
 
{| style="text-align: center; margin:auto;"  
 
{| style="text-align: center; margin:auto;"  
 
|-
 
|-
| <math>{p}_{1}^{wall}=\rho \, D{\omega }^{2}\, \int_{}^{}cos\left( \frac{\pi \, y}{\, 2h}\right) dy+</math><math>\, {C}_{1}=\,</math>  <math display="inline">\rho \, D{\omega }^{2}\left( \frac{2h}{\pi }\right) \left[ \mathrm{sin}\,\left( \frac{\pi y}{2h}\right) - 1\right]</math>
+
| <math>{p}_{1}^{wall}=\rho \, D{\omega }^{2}\, \int_{}^{}\cos\left( \frac{\pi \, y}{\, 2h}\right) dy+</math><math>\, {C}_{1}=</math>  <math>\rho \, D{\omega }^{2}\left( \frac{2h}{\pi }\right) \left[ \sin\,\left( \frac{\pi y}{2h}\right) - 1\right]</math>
 
|}
 
|}
 
| style="width: 5px;text-align: right;white-space: nowrap;" | (19)
 
| style="width: 5px;text-align: right;white-space: nowrap;" | (19)
Line 343: Line 342:
 
| style="width: 5px;text-align: right;white-space: nowrap;" | (20)
 
| style="width: 5px;text-align: right;white-space: nowrap;" | (20)
 
|}
 
|}
 
  
 
At the wall, the amplitude of this pressure second term is:
 
At the wall, the amplitude of this pressure second term is:
Line 352: Line 350:
 
{| style="text-align: center; margin:auto;"  
 
{| style="text-align: center; margin:auto;"  
 
|-
 
|-
| <math>{p}_{2}^{wall}=\rho \, D\omega \left( \frac{\pi }{2h}\right) sin\left( \frac{\pi y}{2h}\right)</math>
+
| <math>{p}_{2}^{wall}=\rho \, D\omega \left( \frac{\pi }{2h}\right) \sin\left( \frac{\pi y}{2h}\right)</math>
 
|}
 
|}
 
| style="width: 5px;text-align: right;white-space: nowrap;" | (21)
 
| style="width: 5px;text-align: right;white-space: nowrap;" | (21)
Line 359: Line 357:
 
These two pressures (<math display="inline">{p}_{1}</math> and <math display="inline">{p}_{2}</math>) can be assumed as the “convective” pressure because both vary according to the liquid sloshing frequency. The pressure <math display="inline">{p}_{2}</math> can be neglected [6] because its value is small, compared with the other terms.
 
These two pressures (<math display="inline">{p}_{1}</math> and <math display="inline">{p}_{2}</math>) can be assumed as the “convective” pressure because both vary according to the liquid sloshing frequency. The pressure <math display="inline">{p}_{2}</math> can be neglected [6] because its value is small, compared with the other terms.
  
The third pressure term <math display="inline">{p}_{3}</math> (Eq. 17) is related directly to the acceleration of the wall and it is identified as the ''impulsive'' pressure. Usually, this pressure has a larger magnitude than <math display="inline">{p}_{2}</math> because in most cases its acceleration spectral ordinate is larger than the corresponding ordinate for the ''sloshing'' frequency. Since the tank wall is assumed rigid, the pressure computation with Eq. 17 would lead to a magnitude equal to ( <math display="inline">\rho \, l\, {a}_{x}</math>). In theory, the pressure would vary according to the ground shaking.
+
The third pressure term <math display="inline">{p}_{3}</math> (Eq. (17)) is related directly to the acceleration of the wall and it is identified as the ''impulsive'' pressure. Usually, this pressure has a larger magnitude than <math display="inline">{p}_{2}</math> because in most cases its acceleration spectral ordinate is larger than the corresponding ordinate for the ''sloshing'' frequency. Since the tank wall is assumed rigid, the pressure computation with Eq. (17) would lead to a magnitude equal to (<math display="inline">\rho \, l\, {a}_{x}</math>). In theory, the pressure would vary according to the ground shaking.
  
To be consistent with the estimation of pressures <math display="inline">{p}_{1}</math> and <math display="inline">{p}_{2}</math>, wherein an effective mass <math display="inline">{M}_{e}</math> was considered, the same shape function used to compute <math display="inline">{M}_{e}</math> is used here (Eq. 13) to estimate <math display="inline">{p}_{3}</math>. Thus, for ''x'' = ''l'', the shape function leads to the following pressure distribution (with a value of  <math display="inline">\rho \, l\, {a}_{x}</math> at the tank base and zero at the liquid free surface):
+
To be consistent with the estimation of pressures <math display="inline">{p}_{1}</math> and <math display="inline">{p}_{2}</math>, wherein an effective mass <math display="inline">{M}_{e}</math> was considered, the same shape function used to compute <math display="inline">{M}_{e}</math> is used here (Eq. (13)) to estimate <math display="inline">{p}_{3}</math>. Thus, for <math display="inline">x = l</math>, the shape function leads to the following pressure distribution (with a value of  <math display="inline">\rho \, l\, {a}_{x}</math> at the tank base and zero at the liquid free surface):
  
 
{| class="formulaSCP" style="width: 100%; text-align: center;"  
 
{| class="formulaSCP" style="width: 100%; text-align: center;"  
Line 368: Line 366:
 
{| style="text-align: center; margin:auto;"  
 
{| style="text-align: center; margin:auto;"  
 
|-
 
|-
| <math>{p}_{3}^{w}=\rho \, l\, {a}_{x}\, sin\left( \frac{\pi \, y}{\, 2h}\right)</math>
+
| <math>{p}_{3}^{w}=\rho \, l\, {a}_{x}\, \sin\left( \frac{\pi \, y}{\, 2h}\right)</math>
 
|}
 
|}
 
| style="width: 5px;text-align: right;white-space: nowrap;" | (22)
 
| style="width: 5px;text-align: right;white-space: nowrap;" | (22)
 
|}
 
|}
 
  
 
Finally, an estimation of the total hydrodynamic pressure on the wall (no including the hydrostatic one) can be obtained, by combining the pressures having different frequencies, using the square root of the sum of the squares (SRSS) rule. Thus:
 
Finally, an estimation of the total hydrodynamic pressure on the wall (no including the hydrostatic one) can be obtained, by combining the pressures having different frequencies, using the square root of the sum of the squares (SRSS) rule. Thus:
Line 389: Line 386:
  
 
<div id='img-4'></div>
 
<div id='img-4'></div>
{| style="text-align: center; border: 1px solid #BBB; margin: 1em auto; width: auto;max-width: auto;"
+
{| style="text-align: center; border: 1px solid #BBB; margin: 1em auto; width: 50%;"
 
|-
 
|-
 
|style="padding:10px;"|  [[Image:Draft_De-la-Colina_143057818-image4.png|264px]]
 
|style="padding:10px;"|  [[Image:Draft_De-la-Colina_143057818-image4.png|264px]]
Line 395: Line 392:
 
| colspan="1" style="padding:10px;"| '''Figure 4'''. Steps to compute both the liquid sloshing height and the hydrodynamic pressures according to the proposed method  
 
| colspan="1" style="padding:10px;"| '''Figure 4'''. Steps to compute both the liquid sloshing height and the hydrodynamic pressures according to the proposed method  
 
|}
 
|}
 
 
<div class="center" style="width: auto; margin-left: auto; margin-right: auto;">
 
[[Image:Draft_De-la-Colina_143057818-image4.png|264px]] </div>
 
 
<div class="center" style="width: auto; margin-left: auto; margin-right: auto;">
 
Figure 4. Steps to compute both the liquid sloshing height and the hydrodynamic</div>
 
 
<div class="center" style="width: auto; margin-left: auto; margin-right: auto;">
 
pressures according to the proposed method.</div>
 
  
 
==3. Numerical example==
 
==3. Numerical example==
  
A numerical example is presented in this section to compare the solutions obtained with the following methodologies: a) ASCE ''Standard'' [1, 3], b) Housner [4, 5], and c) the method presented in this work. A computation using the CFE Code [2, 37] is also included, although its formulas are similar to those obtained by Housner. These computations are compared with the FEM results published by Koh ''et al''. [35, 36].
+
A numerical example is presented in this section to compare the solutions obtained with the following methodologies: a) ASCE ''Standard'' [1,3], b) Housner [4,5], and c) the method presented in this work. A computation using the CFE Code [2,37] is also included, although its formulas are similar to those obtained by Housner. These computations are compared with the FEM results published by Koh ''et al''. [35,36].
  
The geometry of the tank containing water is defined with the following values: ''l ''= ''a'' = 10 m (''L'' = 2''a'' = 20 m) and ''h'' = ''H'' = 9 m. The system is excited with the ''NS'' component of the 1949 El Centro (Imperial Valley) earthquake ground motion (the perpendicular component is neglected). For comparison purposes, no load and resistance factors are included in the computations. No overstrength factors are used either. In all cases, wall pressures are computed for a unit width ''b'' = 1.
+
The geometry of the tank containing water is defined with the following values: <math display="inline">l = a = 10</math> m (<math display="inline">L = 2a= 20</math> m) and <math display="inline">h = H = 9</math> m. The system is excited with the ''NS'' component of the 1949 El Centro (Imperial Valley) earthquake ground motion (the perpendicular component is neglected). For comparison purposes, no load and resistance factors are included in the computations. No overstrength factors are used either. In all cases, wall pressures are computed for a unit width <math display="inline">b = 1</math>.
  
===3.1 ASCE Standard===
+
===3.1 ASCE standard===
  
 
Section 15.7 of the ''Standard'' (''Tanks and Vessels'') contains design recommendations for tanks supported at the base. According to this ''Standard'' [1], damping for sloshing (convective) effects shall be taken as 0.5% in the case of water. Since the ''impulsive'' effects are related to the mass rigidly attached to the tank, in this section the ''impulsive'' term is associated to the pressure <math display="inline">{p}_{3}</math> in Eq. (17). Similarly, the ''convective'' effects are associated to the terms <math display="inline">{p}_{1}</math> and <math display="inline">{p}_{2}</math> of the same equation. No vertical forces associated to vertical ground accelerations are considered here.
 
Section 15.7 of the ''Standard'' (''Tanks and Vessels'') contains design recommendations for tanks supported at the base. According to this ''Standard'' [1], damping for sloshing (convective) effects shall be taken as 0.5% in the case of water. Since the ''impulsive'' effects are related to the mass rigidly attached to the tank, in this section the ''impulsive'' term is associated to the pressure <math display="inline">{p}_{3}</math> in Eq. (17). Similarly, the ''convective'' effects are associated to the terms <math display="inline">{p}_{1}</math> and <math display="inline">{p}_{2}</math> of the same equation. No vertical forces associated to vertical ground accelerations are considered here.
  
According to the ''Standard'', the natural period <math display="inline">{T}_{c}</math> of the first (convective) mode of sloshing is (using ''L'' as the diameter ''D'' of the equation given by the ''Standard'')
+
According to the ''Standard'', the natural period <math display="inline">{T}_{c}</math> of the first (convective) mode of sloshing is (using <math display="inline">L</math> as the diameter '<math display="inline">D</math> of the equation given by the ''Standard'')
  
 
{| class="formulaSCP" style="width: 100%; text-align: center;"  
 
{| class="formulaSCP" style="width: 100%; text-align: center;"  
Line 423: Line 410:
 
{| style="text-align: center; margin:auto;"  
 
{| style="text-align: center; margin:auto;"  
 
|-
 
|-
| <math display="inline">{T}_{c}=2\pi \, \sqrt{\frac{L}{3.68g\, tanh\left( \frac{3.68h}{L}\right) }}</math>
+
| <math>{T}_{c}=2\pi \, \sqrt{\frac{L}{3.68g\, \tanh\left( \displaystyle\frac{3.68h}{L}\right) }}</math>
 
|}
 
|}
 
| style="width: 5px;text-align: right;white-space: nowrap;" | (24)
 
| style="width: 5px;text-align: right;white-space: nowrap;" | (24)
 
|}
 
|}
  
 +
This formula uses English units, so <math display="inline">g = 32.17 ft/s^2</math> , <math display="inline">L = 65.5 ft</math> and <math display="inline">h = 29.5 ft</math>: <math display="inline">{T}_{c} = 4.85</math>  s.
  
This formula uses English units, so ''g'' = 32.17 ft/s<sup>2</sup> , ''L'' = 65.5 ft and ''h'' = 29.5 ft: <math display="inline">{T}_{c}</math> = 4.85 s.
+
The ACI 350.3 [3], which is also referred by the ''Standard'', leads to the value of <math display="inline">{T}_{c}= 5.35</math> s, which is almost equal to the one obtained after using Eq. (13) [12,16].
 
+
The ACI 350.3 [3], which is also referred by the ''Standard'', leads to the value of <math display="inline">{T}_{c}</math> = 5.35 s, which is almost equal to the one obtained after using Eq. (13) [12,16].
+
  
 
As for the water sloshing maximum height, the ''Standard'' gives the following formula:
 
As for the water sloshing maximum height, the ''Standard'' gives the following formula:
Line 440: Line 426:
 
{| style="text-align: center; margin:auto;"  
 
{| style="text-align: center; margin:auto;"  
 
|-
 
|-
| <math display="inline">{\delta }_{s}=0.42\, L\, {I}_{e}\, {S}_{ac}</math>
+
| <math>{\delta }_{s}=0.42\, L\, {I}_{e}\, {S}_{ac}</math>
 
|}
 
|}
 
| style="width: 5px;text-align: right;white-space: nowrap;" | (25)
 
| style="width: 5px;text-align: right;white-space: nowrap;" | (25)
 
|}
 
|}
  
 
+
where <math display="inline">{I}_{e}</math> is the ''Importance Factor'' and <math display="inline">{S}_{ac}</math> is the spectral acceleration of the sloshing liquid based on its vibration period <math display="inline">{T}_{c}</math> and a damping factor <math display="inline">\xi = 0.5%</math>. Considering <math display="inline">{T}_{c}</math> = 5 s, the spectral ordinate is <math display="inline">{S}_{ac}\approx  0.075</math>. Moreover, using <math display="inline">{I}_{e} = 1.0</math>, the sloshing height results equal to <math display="inline">{\delta }_{s}=0.63</math> m. Equation (25) is practically the same as the one given by Chen ''et al''. [6] for zero damping. Notice that the ACI-350.3 gives the following formula to estimate the maximum sloshing height
where <math display="inline">{I}_{e}</math> is the ''Importance Factor'' and <math display="inline">{S}_{ac}</math> is the spectral acceleration of the sloshing liquid based on its vibration period <math display="inline">{T}_{c}</math> and a damping factor <math display="inline">\xi</math>  = 0.5%. Considering <math display="inline">{T}_{c}</math> = 5 s, the spectral ordinate is <math display="inline">{S}_{ac}\approx</math> 0.075. Moreover, using <math display="inline">{I}_{e}</math> = 1.0, the sloshing height results equal to <math display="inline">{\delta }_{s}=</math><math>\,</math> 0.63 m. Equation (25) is practically the same as the one given by Ref [6] for zero damping. Notice that the ACI-350.3 gives the following formula to estimate the maximum sloshing height
+
  
 
{| class="formulaSCP" style="width: 100%; text-align: center;"  
 
{| class="formulaSCP" style="width: 100%; text-align: center;"  
Line 453: Line 438:
 
{| style="text-align: center; margin:auto;"  
 
{| style="text-align: center; margin:auto;"  
 
|-
 
|-
| <math display="inline">{d}_{max}=\, \frac{L}{2}\, Z\, S\, I\, {C}_{c}=\, \frac{L}{2}\, \left( Z\, {C}_{c}\right) S\, I</math>
+
| <math>{d}_{max}=\, \frac{L}{2}\, Z\, S\, I\, {C}_{c}=\, \frac{L}{2}\, \left( Z\, {C}_{c}\right) S\, I</math>
 
|}
 
|}
 
| style="width: 5px;text-align: right;white-space: nowrap;" | (26)
 
| style="width: 5px;text-align: right;white-space: nowrap;" | (26)
 
|}
 
|}
  
 +
where the product between parenthesis can be seen as the spectral acceleration since <math display="inline">Z</math> is the zone peak ground acceleration and <math display="inline">{C}_{c}</math> is the coefficient of spectral acceleration, which is dependent of the vibration period. The factor <math display="inline">S</math> is the soil coefficient and <math display="inline">I</math> is the importance factor taken equal to  <math display="inline">{I}_{e}.</math> Thus, with <math display="inline">(Z{C}_{c})=</math><math>\, {S}_{ac}</math> = 0.075, the sloshing height results <math display="inline">{d}_{max}= 0.75</math>  m.
  
where the product between parenthesis can be seen as the spectral acceleration since ''Z'' is the zone peak ground acceleration and <math display="inline">{C}_{c}</math> is the coefficient of spectral acceleration, which is dependent of the vibration period. The factor ''S'' is the soil coefficient and ''I'' is the importance factor taken equal to  <math display="inline">{I}_{e}.</math> Thus, with <math display="inline">(Z{C}_{c})=</math><math>\, {S}_{ac}</math> = 0.075, the sloshing height results <math display="inline">{d}_{max}</math> = 0.75 m.
+
For the computation of pressures and their resultants, the ''Standard'' recommends the use of the method given by the ACI 350.3 [3]. First, the lateral forces are computed. The impulsive force <math display="inline">{P}_{i}</math> is simply evaluated as the product of the effective impulsive weight <math display="inline">{\, W}_{i}</math> and the spectral acceleration <math display="inline">{A}_{i}</math> (normalized with respect to <math display="inline">g</math>); ''i.e.'',
 
+
For the computation of pressures and their resultants, the ''Standard'' recommends the use of the method given by the ACI 350.3 [3]. First, the lateral forces are computed. The impulsive force <math display="inline">{P}_{i}</math> is simply evaluated as the product of the effective impulsive weight <math display="inline">{\, W}_{i}</math> and the spectral acceleration <math display="inline">{A}_{i}</math> (normalized with respect to ''g''); ''i.e.'',
+
  
 
{| class="formulaSCP" style="width: 100%; text-align: center;"  
 
{| class="formulaSCP" style="width: 100%; text-align: center;"  
Line 468: Line 452:
 
{| style="text-align: center; margin:auto;"  
 
{| style="text-align: center; margin:auto;"  
 
|-
 
|-
| <math display="inline">{P}_{i}=\, {A}_{i}\, {W}_{i}</math>
+
| <math>{P}_{i}=\, {A}_{i}\, {W}_{i}</math>
 
|}
 
|}
 
| style="width: 5px;text-align: right;white-space: nowrap;" | (27)
 
| style="width: 5px;text-align: right;white-space: nowrap;" | (27)
 
|}
 
|}
  
 +
The impulsive force is computed with <math display="inline">{A}_{i}= 0.348</math>. According to the ACI 350.3 the impulsive weight is <math display="inline">{W}_{i}= 0.498 </math>  <math display="inline">{W}_{L}</math>, where <math display="inline">{W}_{L}</math> is the total liquid weight, which for <math display="inline">b = 1</math>  results <math display="inline">{W}_{L}= 1,765</math>  kN = 180,000 kgf. Notice that the weight obtained with the effective mass given by Eq. (15) for the proposed method (<math display="inline">{W}_{e}=</math><math>g{M}_{e}= 1,430.7</math>  kN = 145,890 kgf) is about 80% of <math display="inline">{W}_{L}</math>.
  
The impulsive force is computed with <math display="inline">{A}_{i}</math> = 0.348. According to the ACI 350.3 the impulsive weight is <math display="inline">{W}_{i}</math> = 0.498 <math display="inline">{W}_{L}</math>, where <math display="inline">{W}_{L}</math> is the total liquid weight, which for ''b'' = 1 results <math display="inline">{W}_{L}</math> = 1,765 kN = 180,000 kgf. Notice that the weight obtained with the effective mass given by Eq. (15) for the proposed method ( <math display="inline">{W}_{e}=</math><math>g{M}_{e}</math> = 1,430.7 kN = 145,890 kgf) is about 80% of <math display="inline">{W}_{L}</math>.
+
Therefore <math display="inline">{W}_{i}= 879.1</math> kN = 89,640 kgf and <math display="inline">{P}_{i}=(0.348) 879.1 = 305.9</math> kN = 31,195 kgf.
  
Therefore <math display="inline">{W}_{i}</math> = 879.1 kN = 89,640 kgf and <math display="inline">{P}_{i}=</math> (0.348) 879.1 = 305.9 kN = 31,195 kgf.
+
Similarly, the convective force is given by (with <math display="inline">\, {W}_{c}= 0.522</math>  <math display="inline">{W}_{L}= 921.6</math> kN = 93,976 kgf):
 
+
Similarly, the convective force is given by (with <math display="inline">\, {W}_{c}</math> = 0.522 <math display="inline">{W}_{L}</math> = 921.6 kN = 93,976 kgf):
+
  
 
{| class="formulaSCP" style="width: 100%; text-align: center;"  
 
{| class="formulaSCP" style="width: 100%; text-align: center;"  
Line 485: Line 468:
 
{| style="text-align: center; margin:auto;"  
 
{| style="text-align: center; margin:auto;"  
 
|-
 
|-
| <math display="inline">{P}_{c}=\, {A}_{c}\, {W}_{c}</math>
+
| <math>{P}_{c}=\, {A}_{c}\, {W}_{c}</math>
 
|}
 
|}
 
| style="width: 5px;text-align: right;white-space: nowrap;" | (28)
 
| style="width: 5px;text-align: right;white-space: nowrap;" | (28)
 
|}
 
|}
  
 +
Considering <math display="inline">{A}_{c}\,</math> = <math display="inline">{S}_{ac}\approx 0.075</math>, <math display="inline">{P}_{c} = 0.075</math>(921.6 kN) = 69.1 kN = 7,048 kgf. According to the ACI 350.3, the pressures are obtained by applying the forces on each perpendicular wall with linear distributions (here <math display="inline">\tilde{y}</math> is measured from the bottom up, <math display="inline">{h}_{i} = 3.375</math> m and <math display="inline">{h}_{c}= 5.13</math>  m):
  
Considering <math display="inline">{A}_{c}\,</math> = <math display="inline">{S}_{ac}\approx</math>  0.075, <math display="inline">{P}_{c}</math> = 0.075(921.6 kN) = 69.1 kN = 7,048 kgf. According to the ACI 350.3, the pressures are obtained by applying the forces on each perpendicular wall with linear distributions (here <math display="inline">\tilde{y}</math> is measured from the bottom up, <math display="inline">{h}_{i}</math> = 3.375 m and <math display="inline">{h}_{c}</math> = 5.13 m):
+
{| class="formulaSCP" style="width: 100%; text-align: center;"  
 
+
|-
<div class="center" style="width: auto; margin-left: auto; margin-right: auto;">
+
|
Impulsive pressure:        <math display="inline">{p}_{i}=\, \left( \frac{{P}_{i}}{2}\right) \, \frac{\left[ (4H-6{h}_{i}\, )-\, (6H-12{h}_{i})(\frac{\tilde{y}}{H})\right] }{b\, {h}^{2}}</math></div>
+
{| style="text-align: center; margin:auto;"  
 
+
|-
<div class="center" style="width: auto; margin-left: auto; margin-right: auto;">
+
| <math>\mbox{Impulsive pressure}:\,\, {p}_{i}=\, \left( \displaystyle\frac{{P}_{i}}{2}\right) \, \displaystyle\frac{\left[ (4H-6{h}_{i}\, )-\, (6H-12{h}_{i})\left(\displaystyle\frac{\tilde{y}}{H}\right)\right] }{b\, {h}^{2}}</math>
Convective pressure:       <math display="inline">{p}_{c}=\, \left( \frac{{P}_{c}}{2}\right) \, \frac{\left[ (4H-6{h}_{c}\, )-\, (6H-12{h}_{c})(\frac{\tilde{y}}{H})\right] }{b\, {h}^{2}}</math></div>
+
|-
 +
| <math>\mbox{Convective pressure}: \,\,  {p}_{c}=\, \left( \displaystyle\frac{{P}_{c}}{2}\right) \, \displaystyle\frac{\left[ (4H-6{h}_{c}\, )-\, (6H-12{h}_{c})\left(\displaystyle\frac{\tilde{y}}{H}\right)\right] }{b\, {h}^{2}}</math>
 +
|}
 +
|}
  
 
===3.2 Housner===
 
===3.2 Housner===
  
In this subsection, the wall pressures are computed taking into account the references 4 and 5. The impulsive pressure is computed with the following formula, where ''y'' is measured from the liquid surface down (with ''l'' = ''L''/2 and ''h = H''):
+
In this subsection, the wall pressures are computed taking into account Housner [4,5]. The impulsive pressure is computed with the following formula, where <math display="inline">y</math> is measured from the liquid surface down (with <math display="inline">l = L/2</math> and <math display="inline">h = H</math>):
  
 
{| class="formulaSCP" style="width: 100%; text-align: center;"  
 
{| class="formulaSCP" style="width: 100%; text-align: center;"  
Line 508: Line 495:
 
{| style="text-align: center; margin:auto;"  
 
{| style="text-align: center; margin:auto;"  
 
|-
 
|-
| <math display="inline">{p}_{i}=\, \rho \, {A}_{i}\, h\, \left[ \, \frac{y}{h}-\right. </math><math>\left. \, 0.5{\left( \frac{y}{h}\right) }^{2}\right] \sqrt{3}\, \mathrm{tanh}\,(\sqrt{3}\, \frac{l}{h})</math>
+
| <math>{p}_{i}=\, \rho \, {A}_{i}\, h\, \left[ \, \displaystyle\frac{y}{h}- 0.5{\left( \displaystyle\frac{y}{h}\right) }^{2}\right] \sqrt{3}\, \tanh\,\left(\sqrt{3}\, \displaystyle\frac{l}{h}\right)</math>
 
|}
 
|}
 
| style="width: 5px;text-align: right;white-space: nowrap;" | (29)
 
| style="width: 5px;text-align: right;white-space: nowrap;" | (29)
 
|}
 
|}
 
  
 
The convective pressure is:
 
The convective pressure is:
Line 521: Line 507:
 
{| style="text-align: center; margin:auto;"  
 
{| style="text-align: center; margin:auto;"  
 
|-
 
|-
| <math display="inline">{p}_{c}=\, \rho \, \frac{{l}^{2}}{3}\sqrt{\frac{5}{2}}\, \, \frac{\mathrm{cosh}\,[\sqrt{\frac{5}{2}}\, \, \frac{\tilde{y}}{l}\, ]}{\mathrm{sinh}\,[\sqrt{\frac{5}{2}}\, \, \frac{h}{l}\, ]}\, {\omega }^{2}\, {\theta }_{h}sin\omega t</math>
+
| <math>{p}_{c}=\, \rho \, \displaystyle\frac{{l}^{2}}{3}\sqrt{\displaystyle\frac{5}{2}}\, \, \frac{\cosh\,\left[\sqrt{\displaystyle\frac{5}{2}}\, \, \displaystyle\frac{\tilde{y}}{l}\, \right]}{\sinh\,\left[\sqrt{\displaystyle\frac{5}{2}}\, \, \displaystyle\frac{h}{l}\, \right]}\, {\omega }^{2}\, {\theta }_{h}\sin\omega t</math>
 
|}
 
|}
 
| style="width: 5px;text-align: right;white-space: nowrap;" | (30)
 
| style="width: 5px;text-align: right;white-space: nowrap;" | (30)
 
|}
 
|}
  
 
+
where <math display="inline">\tilde{y}=h-y</math> and <math display="inline">{\theta }_{h}</math> is an estimation of the maximum rotation of the liquid surface. To compute this value, an estimation of the sloshing height <math display="inline">d</math> is required. Housner [5] gives the following equation to estimate it (<math>A</math> is the spectral displacement):
where <math display="inline">\tilde{y}=h-y</math> and <math display="inline">{\theta }_{h}</math> is an estimation of the maximum rotation of the liquid surface. To compute this value, an estimation of the sloshing height ''d'' is required. Housner [5] gives the following equation to estimate it (''A'' is the spectral displacement):
+
  
 
{| class="formulaSCP" style="width: 100%; text-align: center;"  
 
{| class="formulaSCP" style="width: 100%; text-align: center;"  
Line 534: Line 519:
 
{| style="text-align: center; margin:auto;"  
 
{| style="text-align: center; margin:auto;"  
 
|-
 
|-
| <math display="inline">d=\, \frac{0.84\, A\left[ \frac{{k}_{c}\, l}{{m}_{c}\, g}\, \right] \, }{1-\, \frac{A}{l}\, {\left[ \frac{{k}_{c}\, l}{{m}_{c}\, g}\, \right] }^{2}}</math>
+
| <math>d=\, \displaystyle\frac{0.84\, A\left[ \displaystyle\frac{{k}_{c}\, l}{{m}_{c}\, g}\, \right] \, }{1-\, \displaystyle\frac{A}{l}\, {\left[ \displaystyle\frac{{k}_{c}\, l}{{m}_{c}\, g}\, \right] }^{2}}</math>
 
|}
 
|}
 
| style="width: 5px;text-align: right;white-space: nowrap;" | (31)
 
| style="width: 5px;text-align: right;white-space: nowrap;" | (31)
 
|}
 
|}
 
  
 
Thus, the value of <math display="inline">{\theta }_{h}</math> can be computed as follows:
 
Thus, the value of <math display="inline">{\theta }_{h}</math> can be computed as follows:
Line 547: Line 531:
 
{| style="text-align: center; margin:auto;"  
 
{| style="text-align: center; margin:auto;"  
 
|-
 
|-
| <math display="inline">{\theta }_{h}=\, \frac{d}{l}</math>
+
| <math>{\theta }_{h}=\, \frac{d}{l}</math>
 
|}
 
|}
 
| style="width: 5px;text-align: right;white-space: nowrap;" | (32)
 
| style="width: 5px;text-align: right;white-space: nowrap;" | (32)
 
|}
 
|}
 
  
 
===3.3 Method presented here===
 
===3.3 Method presented here===
  
First, the maximum sloshing height is computed with Eq. (16). Using the spectral velocity <math display="inline">{V}_{i}</math> = 0.70 m/s and with <math display="inline">\omega</math> = 1.17 rad/s, the sloshing height results ''D'' = 0.51 m. Then the pressures can be computed with Eqs. (19), (21) and (22). These pressures are combined with Eq. (23). The procedure follows the steps indicated in Fig. 4.
+
First, the maximum sloshing height is computed with Eq. (16). Using the spectral velocity <math display="inline">{V}_{i} = 0.70</math> m/s and with <math display="inline">\omega  = 1.17</math> rad/s, the sloshing height results <math display="inline">D = 0.51</math> m. Then the pressures can be computed with Eqs. (19), (21) and (22). These pressures are combined with Eq. (23). The procedure follows the steps indicated in [[#img-4|Figure 4]].
  
 
===3.4 CFE===
 
===3.4 CFE===
  
The dynamic model as well as the formulas to estimate the sloshing height and the wall pressures are based on the Housner model. Therefore the estimation of ''D'' is computed with Eq. (31), with ''D'' = ''d''. The formulas used to compute the pressures are (after some simplifications and with <math display="inline">\gamma =</math><math>\, \rho g</math>):
+
The dynamic model as well as the formulas to estimate the sloshing height and the wall pressures are based on the Housner model. Therefore the estimation of <math display="inline">D</math>  is computed with Eq. (31), with <math display="inline">D = d</math>. The formulas used to compute the pressures are (after some simplifications and with <math display="inline">\gamma = \rho g</math>):
  
 
{| class="formulaSCP" style="width: 100%; text-align: center;"  
 
{| class="formulaSCP" style="width: 100%; text-align: center;"  
Line 566: Line 549:
 
{| style="text-align: center; margin:auto;"  
 
{| style="text-align: center; margin:auto;"  
 
|-
 
|-
| <math display="inline">{p}_{i}=\, {\left( {c}_{s}\right) }_{i}\, {C}_{i}\, \gamma \, L</math>
+
| <math>{p}_{i}=\, {\left( {c}_{s}\right) }_{i}\, {C}_{i}\, \gamma \, L</math>
 
|}
 
|}
 
| style="width: 5px;text-align: right;white-space: nowrap;" | (33)
 
| style="width: 5px;text-align: right;white-space: nowrap;" | (33)
 
|}
 
|}
 
  
 
and
 
and
Line 579: Line 561:
 
{| style="text-align: center; margin:auto;"  
 
{| style="text-align: center; margin:auto;"  
 
|-
 
|-
| <math display="inline">{p}_{c}=\, {\left( {c}_{s}\right) }_{c}\, {C}_{c}\, \gamma \, L</math>
+
| <math>{p}_{c}=\, {\left( {c}_{s}\right) }_{c}\, {C}_{c}\, \gamma \, L</math>
 
|}
 
|}
 
| style="width: 5px;text-align: right;white-space: nowrap;" | (34)
 
| style="width: 5px;text-align: right;white-space: nowrap;" | (34)
 
|}
 
|}
  
 
+
where the coefficients <math display="inline">{\left( {c}_{s}\right) }_{i}</math> and <math display="inline">{\left( {c}_{s}\right) }_{c}</math> are the spectral accelerations computed for the vibrations periods of the impulsive and convective movements, respectively. The coefficients <math display="inline">{C}_{i}</math> and <math display="inline">{C}_{c}</math> are dimensionless values that describe the pressure variations in terms of the normalized height (<math display="inline">z/H</math>). These graphs are similar to those included in Ref [36]. The CFE also recommends that the total pressure should be computed with the SRSS rule.
where the coefficients <math display="inline">{\left( {c}_{s}\right) }_{i}</math> and <math display="inline">{\left( {c}_{s}\right) }_{c}</math> are the spectral accelerations computed for the vibrations periods of the impulsive and convective movements, respectively. The coefficients <math display="inline">{C}_{i}</math> and <math display="inline">{C}_{c}</math> are dimensionless values that describe the pressure variations in terms of the normalized height (''z/H''). These graphs are similar to those included in Ref [36]. The CFE also recommends that the total pressure should be computed with the SRSS rule.
+
  
 
===3.5 Comparisons===
 
===3.5 Comparisons===
Line 591: Line 572:
 
====3.5.1 Sloshing heights====
 
====3.5.1 Sloshing heights====
  
The liquid sloshing heights computed with each method are listed in Table 1. They vary between 51 and 75 cm. It can be observed that the smaller sloshing height is the one estimated with the finite element method [35] considering the wall thickness = 1.0 m (or rigid). Among the methods that assume the walls as rigid, the proposed method gives the nearest estimation to that computed with the FEM [35].
+
The liquid sloshing heights computed with each method are listed in [[#tab-1|Table 1]]. They vary between 51 and 75 cm. It can be observed that the smaller sloshing height is the one estimated with the finite element method [35] considering the wall thickness = 1.0 m (or rigid). Among the methods that assume the walls as rigid, the proposed method gives the nearest estimation to that computed with the FEM [35].
  
<div class="center" style="width: auto; margin-left: auto; margin-right: auto;">
+
<div class="center" style="font-size: 75%;">'''Table 1'''. Liquid sloshing maximum heights computed with several methods</div>
Table 1. Liquid sloshing maximum heights computed with several methods</div>
+
  
{| style="width: 58%;margin: 1em auto 0.1em auto;border-collapse: collapse;"  
+
<div id='tab-1'></div>
 +
{| class="wikitable" style="margin: 1em auto 0.1em auto;border-collapse: collapse;font-size:85%;width:auto;"  
 +
|-style="text-align:center"
 +
! style="text-align: left;"| Method !! D [m]
 
|-
 
|-
|  style="border: 1pt solid black;text-align: center;vertical-align: top;"|'''Method'''
+
|  style="text-align: left;vertical-align: top;"|Housner
|  style="border: 1pt solid black;text-align: center;vertical-align: top;"|'''D [m]'''
+
|  style="text-align: center;vertical-align: top;"|0.71
 
|-
 
|-
|  style="border: 1pt solid black;text-align: center;vertical-align: top;"|Housner
+
|  style="text-align: left;vertical-align: top;"|''Standard'' ASCE 7-16
|  style="border: 1pt solid black;text-align: center;vertical-align: top;"|0.71
+
|  style="text-align: center;vertical-align: top;"|0.63
 
|-
 
|-
|  style="border: 1pt solid black;text-align: center;vertical-align: top;"|''Standard'' ASCE 7-16
+
|  style="text-align: left;vertical-align: top;"|ACI-350.3
|  style="border: 1pt solid black;text-align: center;vertical-align: top;"|0.63
+
|  style="text-align: center;vertical-align: top;"|0.75
 
|-
 
|-
|  style="border: 1pt solid black;text-align: center;vertical-align: top;"|ACI-350.3
+
|  style="text-align: left;vertical-align: top;"|Method presented here
|  style="border: 1pt solid black;text-align: center;vertical-align: top;"|0.75
+
|  style="text-align: center;vertical-align: top;"|0.51
 
|-
 
|-
|  style="border: 1pt solid black;text-align: center;vertical-align: top;"|Method presented here
+
|  style="text-align: left;vertical-align: top;"|CFE-2015
|  style="border: 1pt solid black;text-align: center;vertical-align: top;"|0.51
+
|  style="text-align: center;vertical-align: top;"|0.71
 
|-
 
|-
|  style="border: 1pt solid black;text-align: center;vertical-align: top;"|CFE-2015
+
|  style="text-align: left;vertical-align: top;"|Ko, Kim and Park (<math display="inline">t = 0.5</math> m)*
|  style="border: 1pt solid black;text-align: center;vertical-align: top;"|0.71
+
|  style="text-align: center;vertical-align: top;"|0.70
 
|-
 
|-
|  style="border: 1pt solid black;text-align: center;vertical-align: top;"|Ko, Kim and Park (''t'' = 0.5 m)*
+
|  style="text-align: left;vertical-align: top;"|Ko, Kim and Park (<math display="inline">t = 1.0</math> m and rigid)*
|  style="border: 1pt solid black;text-align: center;vertical-align: top;"|0.70
+
|  style="text-align: center;vertical-align: top;"|0.30
|-
+
|  style="border: 1pt solid black;text-align: center;vertical-align: top;"|Ko, Kim and Park (''t'' = 1.0 m and rigid)*
+
|  style="border: 1pt solid black;text-align: center;vertical-align: top;"|0.30
+
 
|}
 
|}
  
 
+
<div class="center" style="width: auto; margin-left: auto; margin-right: auto;font-size:75%;">
<div class="center" style="width: auto; margin-left: auto; margin-right: auto;">
+
<math>{}^* t</math> is the thickness of the wall in the case of the study with flexible walls [35]</div>
''* t'' is the thickness of the wall in the case of the study with flexible walls [35]</div>
+
  
 
====3.5.2 Convective pressures====
 
====3.5.2 Convective pressures====
  
To show a complete perspective of the computed pressures, the convective pressures are computed separately for those methods were these pressures are available. Figure 5 shows the convective pressures computed for some methods. The smaller convective pressures are estimated by the proposed method; however, this is not relevant because the design of tanks is carried out with the total pressures. The separation of ''convective'' and ''impulsive'' pressures is just a computational device.
+
To show a complete perspective of the computed pressures, the convective pressures are computed separately for those methods were these pressures are available. [[#img-5|Figure 5]] shows the convective pressures computed for some methods. The smaller convective pressures are estimated by the proposed method; however, this is not relevant because the design of tanks is carried out with the total pressures. The separation of ''convective'' and ''impulsive'' pressures is just a computational device.
  
<div class="center" style="width: auto; margin-left: auto; margin-right: auto;">
+
<div id='img-5'></div>
[[Image:Draft_De-la-Colina_143057818-image5-c.png|348px]] </div>
+
{| style="text-align: center; border: 1px solid #BBB; margin: 1em auto; width: auto;max-width: auto;"
 
+
|-
<div class="center" style="width: auto; margin-left: auto; margin-right: auto;">
+
|style="padding:10px;"| [[Image:Draft_De-la-Colina_143057818-image5-c.png|348px]]
Figure 5. Wall convective pressures computed with several methods.</div>
+
|- style="text-align: center; font-size: 75%;"
 +
| colspan="1" style="padding:10px;"| '''Figure 5'''. Wall convective pressures computed with several methods
 +
|}
  
 
====3.5.3 Impulsive pressures====
 
====3.5.3 Impulsive pressures====
  
Figure 6 shows the impulsive pressures computed for some methods. Contrary to the convective pressures, the larger convective pressures at the tank base are estimated by the proposed method.
+
[[#img-6|Figure 6]] shows the impulsive pressures computed for some methods. Contrary to the convective pressures, the larger convective pressures at the tank base are estimated by the proposed method.
  
<div class="center" style="width: auto; margin-left: auto; margin-right: auto;">
+
<div id='img-6'></div>
[[Image:Draft_De-la-Colina_143057818-image6-c.png|384px]] </div>
+
{| style="text-align: center; border: 1px solid #BBB; margin: 1em auto; width: auto;max-width: auto;"
 
+
|-
<div class="center" style="width: auto; margin-left: auto; margin-right: auto;">
+
|style="padding:10px;"| [[Image:Draft_De-la-Colina_143057818-image6-c.png|384px]]
Figure 6. Wall impulsive pressures computed with several methods.</div>
+
|- style="text-align: center; font-size: 75%;"
 +
| colspan="1" style="padding:10px;"| '''Figure 6'''. Wall impulsive pressures computed with several methods
 +
|}
  
 
====3.5.4 Total hydrodynamic pressures====
 
====3.5.4 Total hydrodynamic pressures====
  
As for the total pressures, the total wall pressures are shown in Fig. 7. The pressures computed in Ref [29] are also included in the figure. These values were computed with the finite element method (FEM) and are assumed here as the “exact” pressures.
+
As for the total pressures, the total wall pressures are shown in [[#img-7|Figure 7]]. The pressures computed in Cho and Lee [29] are also included in the figure. These values were computed with the finite element method (FEM) and are assumed here as the “exact” pressures.
  
====3.5.5 Sher forces and bending moments at the tank walls====
+
<div id='img-7'></div>
 +
{| style="text-align: center; border: 1px solid #BBB; margin: 1em auto; width: auto;max-width: auto;"
 +
|-
 +
|style="padding:10px;"| [[Image:Draft_De-la-Colina_143057818-image7-c.png|378px]]
 +
|- style="text-align: center; font-size: 75%;"
 +
| colspan="1" style="padding:10px;"| '''Figure 7'''. Total wall pressures computed with several methods
 +
|}
  
For the wall design, an estimation of both the shear forces (''V'') and the bending moments (''M'') is required. An analysis of the walls can be carried out taking into account a theory of plates (either thin plate theory or thick plate theory). In the estimation of these forces (''V'' and ''M'') a finite element analysis of the complete tank can also be considered, however given the accuracy involved in the estimations of pressures, this refinement is in many cases not justified. An isolated plate with adequate boundary conditions seems to be enough for the computation of forces. Since the length/height ratio of the tank of this example is larger than 2.0, a vertical strip of wall can be idealized as a contilever beam supported at the base with a width equal to 1.0 m. This simplification is used here as a simple way to compare these moments among the methods. In the case of reinforced-concrete tanks the bending moment referred here can be used to obtain the wall vertical reinforcement.
 
  
<div class="center" style="width: auto; margin-left: auto; margin-right: auto;">
+
====3.5.5 Sher forces and bending moments at the tank walls====
''' [[Image:Draft_De-la-Colina_143057818-image7-c.png|378px]] '''</div>
+
  
<div class="center" style="width: auto; margin-left: auto; margin-right: auto;">
+
For the wall design, an estimation of both the shear forces (<math display="inline">V</math>) and the bending moments (<math display="inline">M</math>) is required. An analysis of the walls can be carried out taking into account a theory of plates (either thin plate theory or thick plate theory). In the estimation of these forces (<math display="inline">V</math>) and the bending moments (<math display="inline">M</math>) a finite element analysis of the complete tank can also be considered, however given the accuracy involved in the estimations of pressures, this refinement is in many cases not justified. An isolated plate with adequate boundary conditions seems to be enough for the computation of forces. Since the length/height ratio of the tank of this example is larger than 2.0, a vertical strip of wall can be idealized as a contilever beam supported at the base with a width equal to 1.0 m. This simplification is used here as a simple way to compare these moments among the methods. In the case of reinforced-concrete tanks the bending moment referred here can be used to obtain the wall vertical reinforcement.
Figure 7. Total wall pressures computed with several methods.</div>
+
  
The distributions of shear forces per unit width are shown in Fig. 8. It is clear that the distributions of these shear forces are similar among the methods. The shear forces computed with the proposed method resulted slightly larger than the finite element method (FEM) forces, given by Koh, Kim and Park [35]. The shear force at the wall base predicted by the proposed method resulted 13% larger than the value given by the FEM solution.
+
The distributions of shear forces per unit width are shown in [[#img-8|Figure 8]]. It is clear that the distributions of these shear forces are similar among the methods. The shear forces computed with the proposed method resulted slightly larger than the finite element method (FEM) forces, given by Koh ''et al.'' [35]. The shear force at the wall base predicted by the proposed method resulted 13% larger than the value given by the FEM solution.
  
<div class="center" style="width: auto; margin-left: auto; margin-right: auto;">
+
<div id='img-8'></div>
[[Image:Draft_De-la-Colina_143057818-image8-c.png|396px]] </div>
+
{| style="text-align: center; border: 1px solid #BBB; margin: 1em auto; width: auto;max-width: auto;"
 +
|-
 +
|style="padding:10px;"|[[Image:Draft_De-la-Colina_143057818-image8-c.png|396px]]
 +
|- style="text-align: center; font-size: 75%;"
 +
| colspan="1" style="padding:10px;"| '''Figure 8'''. Shear forces per unit width of wall computed with several methods
 +
|}
  
<div class="center" style="width: auto; margin-left: auto; margin-right: auto;">
 
Figure 8. Shear forces per unit width of wall computed with several methods.</div>
 
  
The distributions of bending moments per unit width are shown in Fig. 9. All distributions are similar among the methods. Again, the closer approximation to the finite element method (FEM) results [35], is the one obtained with the proposed method. The bending moment at the wall base predicted by the proposed method resulted only 6% larger than the value given by the FEM solution.
+
The distributions of bending moments per unit width are shown in [[#img-9|Figure 9]]. All distributions are similar among the methods. Again, the closer approximation to the finite element method (FEM) results [35], is the one obtained with the proposed method. The bending moment at the wall base predicted by the proposed method resulted only 6% larger than the value given by the FEM solution.
  
<div class="center" style="width: auto; margin-left: auto; margin-right: auto;">
+
<div id='img-9'></div>
[[Image:Draft_De-la-Colina_143057818-image9-c.png|348px]] </div>
+
{| style="text-align: center; border: 1px solid #BBB; margin: 1em auto; width: auto;max-width: auto;"
 
+
|-
<div class="center" style="width: auto; margin-left: auto; margin-right: auto;">
+
|style="padding:10px;"|[[Image:Draft_De-la-Colina_143057818-image9-c.png|348px]]
Figure 9. Bending moments per unit width of wall computed with several methods.</div>
+
|- style="text-align: center; font-size: 75%;"
 +
| colspan="1" style="padding:10px;"| '''Figure 9'''. Bending moments per unit width of wall computed with several methods
 +
|}
  
 
==4. Conclusions==
 
==4. Conclusions==
Line 684: Line 675:
  
 
==References==
 
==References==
 +
 +
<div class="auto" style="text-align: left;width: auto; margin-left: auto; margin-right: auto;font-size: 85%;">
  
 
[1] American Society of Civil Engineers. ASCE/SEI 07-16. Minimum design loads and associated criteria for buildings and other structures. ASCE: Reston, Virginia, 2017.
 
[1] American Society of Civil Engineers. ASCE/SEI 07-16. Minimum design loads and associated criteria for buildings and other structures. ASCE: Reston, Virginia, 2017.
Line 689: Line 682:
 
[2] Comisión Federal de Electricidad. Manual de diseño de obras civiles – Diseño por sismo. CFE: Ciudad de Mexico, 2009.  Spanish.
 
[2] Comisión Federal de Electricidad. Manual de diseño de obras civiles – Diseño por sismo. CFE: Ciudad de Mexico, 2009.  Spanish.
  
[3] American Concrete Institute. ACI 350.3-06: Seismic Design of Liquid-Containing Concrete Structures and Commentary ACI: Farmington Hills, 2006.
+
[3] American Concrete Institute. ACI 350.3-06: Seismic design of liquid-containing concrete structures and commentary ACI: Farmington Hills, 2006.
  
[4] Housner, G.W. Dynamic pressures on accelerated fluid containers''. ''Bull. Seismol. Soc. Am., 47:15-35, 1957.
+
[4] Housner G.W. Dynamic pressures on accelerated fluid containers. Bull. Seismol. Soc. Am., 47:15-35, 1957.
  
[5] Housner, G.W. The dynamic behavior of water tanks. Bull. Seismol. Soc. Am., 53:381-387, 1963.
+
[5] Housner G.W. The dynamic behavior of water tanks. Bull. Seismol. Soc. Am., 53:381-387, 1963.
  
[6] Chen, W., Haroun, M, Liu, F. Large amplitude liquid sloshing in seismically excited tanks. Earthq. Eng. Struct. Dyn., 25:653-669, 1996.
+
[6] Chen W., Haroun M, Liu F. Large amplitude liquid sloshing in seismically excited tanks. Earthq. Eng. Struct. Dyn., 25:653-669, 1996.
  
 
[7] American Water Works Association. Welded carbon steel tanks for water storage. ANSI/AWWA D100-05 Standard. Denver, 2005.
 
[7] American Water Works Association. Welded carbon steel tanks for water storage. ANSI/AWWA D100-05 Standard. Denver, 2005.
  
[8] Veletsos, A.,  Yang, J. Earthquake response of liquid storage tanks. Proceedings 2nd Engineering Mechanics Specialty Conference. ASCE. Raleigh, (NC). 1977.
+
[8] Veletsos A.,  Yang J. Earthquake response of liquid storage tanks. Proceedings 2nd Engineering Mechanics Specialty Conference, ASCE. Raleigh, (NC), 1977.
  
[9] Malhotra, P.K., Wenk. T. ,Wieland, M. Simple procedure for seismic analysis of liquid-storage tanks. Struct. Eng. Int., 10(3):197-201, 2000.
+
[9] Malhotra P.K., Wenk T., Wieland M. Simple procedure for seismic analysis of liquid-storage tanks. Struct. Eng. Int., 10(3):197-201, 2000.
  
 
[10] European Committee for Standarization (CEN). Eurocode 8. Design of Structures for Earthquake Resistance. Part 4: Silos, tanks and pipelines. CEN: Brussels, 2006.
 
[10] European Committee for Standarization (CEN). Eurocode 8. Design of Structures for Earthquake Resistance. Part 4: Silos, tanks and pipelines. CEN: Brussels, 2006.
  
[11] Epstein, H. Seismic design of liquid-storage tanks. J. Struct. Div., 102:1659-1673, 1976.
+
[11] Epstein H. Seismic design of liquid-storage tanks. J. Struct. Div., 102:1659-1673, 1976.
  
[12] Graham, E., Rodriguez, A. The characteristics of fuel motion which affect airplane dynamics. Report SM 14212. Douglas Aircraft Company, Santa Monica (CA). 1951.
+
[12] Graham E., Rodriguez A. The characteristics of fuel motion which affect airplane dynamics. Report SM 14212, Douglas Aircraft Company, Santa Monica (CA), 1951.
  
[13] Ibrahim, R. Liquid sloshing dynamics: Theory and applications. New York (NY): Cambridge University Press; 2005.
+
[13] Ibrahim R. Liquid sloshing dynamics: Theory and applications. New York (NY): Cambridge University Press, 2005.
  
[14] Langhaar, H. Energy Methods in Applied Mechanics. Krieger: Malabar (FL), 1962.
+
[14] Langhaar H. Energy methods in applied mechanics. Krieger: Malabar (FL), 1962.
  
[15] Minowa, C. Dynamic analysis for rectangular water tanks. Recent Adv. Lifeline Earthquake Engineering. Japan. 1980.
+
[15] Minowa C. Dynamic analysis for rectangular water tanks. Recent Adv. Lifeline Earthquake Engineering, Japan, 1980.
  
[16] Zhu, F. Rayleigh-Ritz method in coupled fluid-structure interacting systems and its applications. J. Sound Vib.,'' ''186:543-550, 1995.
+
[16] Zhu F. Rayleigh-Ritz method in coupled fluid-structure interacting systems and its applications. J. Sound Vib., 186:543-550, 1995.
  
[17] Moradi, R., Behnamfar, F., Hashem, S. Mechanical model for cylindrical flexible concrete tanks undergoing lateral excitation. Soil Dyn. Earthq. Eng.,'' ''106:148–162, 2018.
+
[17] Moradi R., Behnamfar F., Hashem S. Mechanical model for cylindrical flexible concrete tanks undergoing lateral excitation. Soil Dyn. Earthq. Eng., 106:148–162, 2018.
  
[18] Kim, J.K., Koh, H.M., Kwahk, I.J. Dynamic response of rectangular flexible fluid containers. J. Eng. Mech., 122(9): 807-817, 1996.
+
[18] Kim J.K., Koh H.M., Kwahk I.J. Dynamic response of rectangular flexible fluid containers. J. Eng. Mech., 122(9):807-817, 1996.
  
[19] Rashed, A.A., Iwan, W.D. Dynamic analysis of short-length gravity dams. J. Eng. Mech''.'','' ''111 (8):1067-1083, 1985.
+
[19] Rashed A.A., Iwan W.D. Dynamic analysis of short-length gravity dams. J. Eng. Mech., 111(8):1067-1083, 1985.
  
[20] Zhao, D., Hu, Z., Chen, G., et al. Nonlinear sloshing in rectangular tanks under forced excitation. In.t J. Nav Arch. Ocean Eng., 10:545-565, 2018.
+
[20] Zhao D., Hu Z., Chen G., Lim S., Wang S. Nonlinear sloshing in rectangular tanks under forced excitation. In.t J. Nav Arch. Ocean Eng., 10:545-565, 2018.
  
[21] Ning, D.Z., Song,. WH., Liu, Y., et al. A boundary element investigation of liquid sloshing in coupled horizontal and vertical excitation. J. Appl. Math., 2012:1-20. DOI:10.1155/2012/340640, 2012.
+
[21] Ning D.Z., Song W.H., Liu Y., Teng B. A boundary element investigation of liquid sloshing in coupled horizontal and vertical excitation. J. Appl. Math., 2012:1-20, 2012. [https://www.hindawi.com/journals/jam/2012/340640/ DOI: 10.1155/2012/340640]
  
[22] Hu, Z., Zhang, X., Li, X., et al. On natural frequencies of liquid sloshing in 2-D tanks using boundary element method. Ocean. Eng., 153:88–103, 2018. [https://doi.org/10.1016/j.oceaneng.2018.01.062 https://doi.org/10.1016/j.oceaneng.2018.01.062].
+
[22] Hu Z., Zhang X., Li X., Li Y. On natural frequencies of liquid sloshing in 2-D tanks using boundary element method. Ocean. Eng., 153:88–103, 2018. [https://doi.org/10.1016/j.oceaneng.2018.01.062 https://doi.org/10.1016/j.oceaneng.2018.01.062].
  
[23] Hwang, I.T., Ting, K. Boundary element method for fluid-structure interaction problems in liquid storage tanks.'' ''J. Press. Vessel. Technol., 111(4):435-440, 1989. [https://doi.org/10.1115/1.3265701 https://doi.org/10.1115/1.3265701].
+
[23] Hwang I.T., Ting K. Boundary element method for fluid-structure interaction problems in liquid storage tanks. J. Press. Vessel. Technol., 111(4):435-440, 1989. [https://doi.org/10.1115/1.3265701 https://doi.org/10.1115/1.3265701].
  
[24] Taylor, R.E., Wu, G.X., Bai, W., et al. Numerical wave tanks based on finite element and boundary element modeling. J. Offshore Mech. Arctic Eng., 130(3), 2008.
+
[24] Taylor R.E., Wu G.X., Bai W., Hu Z.Z. Numerical wave tanks based on finite element and boundary element modeling. J. Offshore Mech. Arctic Eng., 130(3):031001, 2008.
  
[25] Wu, G.X., Ma,.. QW, Taylor, R.E. Numerical simulation of sloshing waves in a 3D tank based on a finite element method.  Appl. Ocean Res., 20:337–355, 1998.
+
[25] Wu G.X., Ma Q.W., Taylor R.E. Numerical simulation of sloshing waves in a 3D tank based on a finite element method.  Appl. Ocean Res., 20:337–355, 1998.
  
[26] Aslam, M. Finite element analysis of earthquake-induced sloshing in axisymmetric tanks. Int. J. Numer. Methods Eng., 17:159-170, 1981.
+
[26] Aslam M. Finite element analysis of earthquake-induced sloshing in axisymmetric tanks. Int. J. Numer. Methods Eng., 17:159-170, 1981.
  
[27] Babu, S.S., Bhattacharyya, S. Finite element analysis of fluid-structure interaction effect on liquid retaining structures due to sloshing. Comput. Struc., 59(6):1165-1171, 1996.
+
[27] Babu S.S., Bhattacharyya S. Finite element analysis of fluid-structure interaction effect on liquid retaining structures due to sloshing. Comput. Struc., 59(6):1165-1171, 1996.
  
[28] Arafa,.. M. Finite Element Analysis of Sloshing in Rectangular Liquid-Filled Tanks.  J. Vib. Control, 13(7): 883–903, 2007. DOI: 10.1177/1077546307078833.
+
[28] Arafa M. Finite element analysis of sloshing in rectangular liquid-filled tanks.  J. Vib. Control, 13(7):883–903, 2007. [https://journals.sagepub.com/doi/10.1177/1077546307078833 DOI: 10.1177/1077546307078833].
  
[29] Cho, J.R., Lee, H.W. Non-linear finite element analysis of large amplitude sloshing flow in two-dimensional tank. Int. J. Numer. Methods Eng., 61:514–531, 2004. DOI: 10.1002/nme.1078.
+
[29] Cho J.R., Lee H.W. Non-linear finite element analysis of large amplitude sloshing flow in two-dimensional tank. Int. J. Numer. Methods Eng., 61(4):514–531, 2004. [https://onlinelibrary.wiley.com/doi/abs/10.1002/nme.1078 DOI: 10.1002/nme.1078].
  
[30] Hernández, H., Hernández, A., Valdés, G. Non-linear sloshing effect on storage tanks subjected to high earthquake ground motion. Rev. Int. Métodos Numer. Calc. Diseño Ing., 31(3):198–206, 2015. Spanish. [http://dx.doi.org/10.1016/j.rimni.2014.09.002 http://dx.doi.org/10.1016/j.rimni.2014.09.002].
+
[30] Hernández H., Hernández A., Valdés G. Non-linear sloshing effect on storage tanks subjected to high earthquake ground motion. Rev. Int. Métodos Numer. Calc. Diseño Ing., 31(3):198–206, 2015. Spanish. [http://dx.doi.org/10.1016/j.rimni.2014.09.002 http://dx.doi.org/10.1016/j.rimni.2014.09.002].
  
[31] Frandsen, J.B,  Bortwick, A.G. Simulation of sloshing motions in fixed and vertically excited containers using a  2-D inviscid &#x03c3;-transformed finite difference solver. J. Fluids Struct., 18:197–214, 2003.
+
[31] Frandsen J.B,  Bortwick A.G. Simulation of sloshing motions in fixed and vertically excited containers using a  2-D inviscid <math>\sigma</math>-transformed finite difference solver. J. Fluids Struct., 18:197–214, 2003.
  
[32] Cook. R.D., Malkus, D.S., Plesha,. ME., et al. Concepts and Applications of the Finite Element Analysis. 4th ed. John Wiley and Sons: New York (NY), 2002.
+
[32] Cook R.D., Malkus D.S., Plesha M.E., Witt R.J. Concepts and applications of the finite element analysis. 4th ed. John Wiley and Sons: New York (NY), 2002.
  
[33] Housner, G.W. Limit design of structures to resist earthquakes. ''Proc First World Conference on Earthquake Engineering'', Berkeley (CA), 1956.
+
[33] Housner G.W. Limit design of structures to resist earthquakes. Proc First World Conference on Earthquake Engineering, Berkeley (CA), 1956.
  
[34] Uang,. CM., Bertero, V.V. Evaluation of seismic energy in structures. Earthq. Eng. Struct. Dyn., 19:77-90, 1990.
+
[34] Uang C.M., Bertero V.V. Evaluation of seismic energy in structures. Earthq. Eng. Struct. Dyn., 19(1):77-90, 1990.
  
[35] Koh, H..M, Kim, J.K., Park, J.H. Fluid—structure interaction analysis of 3-d rectangular tanks by a variationally coupled BEM-FEM and comparison with test results. Earthq. Eng. Struct. Dyn., 27:109-124, 1998.
+
[35] Koh H.M., Kim J.K., Park J.H. Fluid—structure interaction analysis of 3-d rectangular tanks by a variationally coupled BEM-FEM and comparison with test results. Earthq. Eng. Struct. Dyn., 27(2):109-124, 1998.
  
[36] Dogangun, A., Livaoglu, R. Hydrodynamic pressures acting on the walls of rectangular fluid containers. Struct. Eng. Mech., 17(2):203-214, 2004.
+
[36] Dogangun A., Livaoglu R. Hydrodynamic pressures acting on the walls of rectangular fluid containers. Struct. Eng. Mech., 17(2):203-214, 2004.
  
[37] Flores, C. B. Comportamiento mecánico de tanques atmosféricos de almacenamiento. Tesis de maestría. Escuela Superior de Ingeniería y Arquitectura (ESIA), Instituto Politécnico Nacional (IPN), Ciudad de México, 2009.
+
[37] Flores C.B. Comportamiento mecánico de tanques atmosféricos de almacenamiento. Tesis de maestría. Escuela Superior de Ingeniería y Arquitectura (ESIA), Instituto Politécnico Nacional (IPN), Ciudad de México, 2009.

Latest revision as of 15:32, 18 July 2022

Abstract

A proposal to estimate both the hydrodynamic pressures and the maximum wave height of liquids contained in rectangular tanks subjected to earthquake ground motions is presented. The computation procedure, based on the Rayleigh-Ritz method, assumes the fluid as a continuum and it does not use concentrated masses or springs. The solution is achieved by equating the seismic input energy of the system with the total kinetic energy of the fluid assuming liquid velocity fields. The resulting design formulas are simple and they are intended to simplify the seismic design of tanks. Numerical results lead to both the liquid maximum sloshing height and hydrodynamic pressure distributions that are similar to those obtained with other simplified methods and those estimated with the finite element method. Preliminary estimations of shear forces and bending moments for a numerical example resulted 13% and 6% larger (respectively) than the corresponding values obtained with the finite element method.

Keywords: Liquid-containing tanks, sloshing, hydrodynamic pressures, seismic design, Rayleigh-Ritz

1. Introduction

The seismic design of ground-supported tanks containing liquids requires the estimation of both the hydrodynamic pressures and the maximum sloshing height of the liquid, as indicated in typical design documents [1,2]. Currently, these documents include recommendations to compute the maximum sloshing height. The ASCE Standard relies on the document ACI 350.3 [3] for the computation of the hydrodynamic pressures.

In general, the formulas recommended by these documents to estimate the hydrodynamic pressures are based on the solutions presented by Housner [4,5]. On the other hand, the formula given by the ASCE Standard [1] to estimate the maximum height of the sloshing liquid is based on the classical solution of the Laplace differential equation given by Chen et al. [6] assuming no damping and the first vibration mode of the liquid. Other similar design recommendations for the seismic design of tanks (e.g., [7]) are also based on the Housner solutions to estimate hydrodynamic pressures and the sloshing height. A similar approach to that proposed by Housner, based on the works by Veletsos and Yang [8] as well as those of Malhorta [9], were incorporated in the Eurocode [10]. Epstein [11], based on the same works by Housner, presented updated formulas for the seismic design of cylindrical and rectangular tanks. Formulas obtained from solving the differential equations to estimate frequencies, pressures and sloshing heights were presented by Graham and Rodriguez [12,13]. These formulas, however, are not simple to use in design codes.

The equations derived by Housner have been widely used and they provide results with a precision that is good enough for engineering purposes. Housner obtained the design formulas assuming the tank as rigid and incorporating some simplifications of the liquid behavior during the tank vibration. The main simplification assumes that, during vibration, the liquid is divided in two parts: 1) a lower liquid mass that moves as a rigid body along with the tank, and 2) an upper liquid mass that moves relatively to the tank. The lower mass is identified as an impulsive mass and it causes pressures that are directly proportional to both the magnitude of this mass and the acceleration of the (rigid) tank. The upper mass is identified as a convective mass and it causes pressures that are due to the sloshing of the liquid. In the associated Housner’s analytical model (Figure 1), the continuum (liquid) consists of two concentrated masses: one rigidly attached to the lower part of the tank and the other that is connected with a spring to the upper part of the tank. Housner provided formulas to estimate: 1) the magnitudes of both masses, 2) the heights of each one and 3) the stiffness of the spring that connects the upper mass to the tank. Since each mass vibrates with a different frequency, the seismic response of each mass, as well as the forces on the tank walls, can be estimated with a seismic spectral analysis and a modal combination rule.

Draft De-la-Colina 143057818-image1.png
Figure 1. Housner’s model with two concentrated masses to study the liquid movement


The Rayleigh-Ritz method (RRM) [14] has been used to study vibrations of tanks. For instance, Minowa [15] studied the dynamic characteristics of elevated rectangular water tanks supported on frames and including water sloshing. Zhu [16] used the Rayleigh-Ritz method to estimate the natural frequencies of tanks considering fluid-structure interaction. In the study, full or partially filled tanks with inviscid, irrotational and compressible or incompressible fluids were considered. Zhu reported equations to compute the eigenvalues and eigenvectors of fluid-tank systems. Moradi et al. [17] proposed a mechanical model consisting of three concentrated masses to evaluate the seismic response of flexible cylindrical tanks. In their study, the Rayleigh-Ritz method was used for the analysis of liquid-shell systems. For design purposes, they present charts to estimate the dynamic parameters of the model.

Kim et al. [18] also studied the dynamic response of rectangular flexible tanks using the RRM. Rashed and Iwan [19] used the Rayleigh-Ritz method to express the tank wall displacements as a linear combination of admissible functions, while the liquid pressure equations were obtained with analytical solutions based on the method of separation of variables. In all these studies the RRM was applied to approximate the displacement field of the tank plates (walls or slab) while the liquid equation of motion was obtained with analytical methods, applying in many cases the method of separation of variables.

The seismic response of liquid-containing tanks has been also studied with numerical procedures. The main numerical methods include finite elements, boundary elements or finite differences. For example, Zhao et al. [20] used the boundary-element method (BEM) to study the nonlinear sloshing in rectangular tanks under base excitations. In their study, the hydrodynamic pressures were validated with experimental tests. Ning et al. [21] also used the BEM to study sloshing of liquids in tanks subjected to both horizontal and vertical excitations. Hu et al. [22] studied the natural frequencies of 2D tanks using the BEM.

The finite-element method (FEM) has also been used to study tanks subjected to ground motions. For instance, Hwang and Ting [23] combined the BEM and the FEM to study the dynamic response of liquid storage tanks subjected to earthquake ground motions. Taylor et al. [24] also combined both finite and boundary elements to model the interaction of nonlinear waves in tanks. Wu et al. [25] analyzed the sloshing waves in 3D tank using the FEM. Aslam [26] also studied sloshing in cylindrical tanks induced by ground motions. Babu and Bhattacharyya [27] studied the fluid-structure interaction effect on liquid-retaining structures due to sloshing using finite element analysis. Other studies using the FEM include Arafa [28] and Cho and Lee [29].

The finite-difference method (FDM) has been used, for instance, by Chen et al. [6], by Hernandez et al. [30] and by Frandsen and Bortwick [31] to study the nonlinear sloshing of a liquid contained in cylindrical and rectangular tanks subjected to ground motions.

The studies referred in the previous paragraphs either used the Rayleigh-Ritz method or numerical procedures to estimate dynamic characteristics of tanks containing fluids. Such works are not directly applicable for design because the associated procedures or formulas are elaborate.

The aim of the present work is to present simple design equations to estimate both the distribution of tank wall hydrodynamic pressures and the liquid maximum sloshing height. The proposed formulas are obtained with a model that does not use concentrated masses or springs. It assumes the liquid as a continuum. The solution is obtained by establishing an equilibrium between the system seismic input energy and the maximum fluid kinetic energy. The solution follows the Rayleigh-Ritz method [14] in the sense that the infinite number of degrees of freedom (d.o.f.) of the liquid is reduced to a small number of d.o.f. by assuming an approximating field [32]. In this work, the approximating fields are both the lateral and the vertical displacements/velocities of the fluid.

2. A method to estimate pressures

2.1 Tank geometry and liquid velocity fields

In this section, the Rayleigh-Ritz method is used to obtain expressions to estimate the liquid-sloshing height and the wall pressures in a liquid-storage rectangular tank subjected to an earthquake ground motion. The tank is assumed as rigid and trial functions are proposed for both the vertical () and the horizontal () fluid velocities. The basic assumption used to obtain the main design parameters is to equate the seismic input energy of the liquid with its maximum kinetic energy. In the solution, a velocity potential is not required.

An open rectangular tank is shown in Figure 2, wherein the system of reference is located at the center of the initial liquid surface. In this figure, a surface of the liquid during sloshing is also illustrated. It is assumed that the fluid moves according to its first sloshing mode in a steady-state motion with constant peak wave . The variable represents the maximum sloshing liquid height at . In this work, this sloshing height is assumed as the main variable to be determined and it is taken as a generalized coordinate [30] within the Rayleigh-Ritz method. The initial height of the water is and the tank width is equal to . The total tank length is assumed equal to , although the analysis can be completed for a length equal to 1.0, when the ground motion direction is along the direction.

Draft De-la-Colina 143057818-image2.png
Figure 2. Geometry of a rigid rectangular tank


For the first sloshing mode, the shape of the water surface can be approximated with the following admissible fields for horizontal and vertical displacements, respectively

(1)
(2)

where is the liquid circular frequency and is the time. These fields lead to maximum fluid horizontal displacement at the bottom for and maximum vertical displacement of the liquid of the surface at . They also lead to , at the tank bottom (). The horizontal and vertical velocity fields result. The liquid movement resulting of these displacement fields is illustrated in Figure 3. In these equations is the time.

Draft De-la-Colina 143057818-image3.png
Figure 3. Fluid displacement


In these fields, the variable is the maximum horizontal displacement of the fluid (Figure 3). The liquid volume reduction that occurs at one side of the tank when the surface lowers should be equal to the volume increment at the other side of the tank (Figure 3). Therefore the maximum horizontal displacement () can be expressed in terms of the maximum vertical displacement ():

(3)

The velocity fields resulting of these displacement fields are given by the following equations after taking derivatives with respect to the time :

(4)
(5)


Using Eq. (3) in (4), the field of the horizontal velocities results as follows

(6)

2.2 Energy balance and liquid maximum sloshing height

The total kinetic energy of the fluid can be estimated by integrating the amount 0.5(), that corresponds to the kinetic energy of each mass differential , over the liquid volume:

(7)

In these expressions, is the velocity of each particle and

(8)

Assuming that the liquid is homogeneous with density equal to , the total maximum kinetic energy of the fluid due to the horizontal velocity is

(9)

Similarly, the maximum kinetic energy due to the vertical velocity is

(10)

The total kinetic energy of the fluid, assuming that both and occur at the same time, results

(11)

The (input) energy that an earthquake introduces to the liquid can be estimated with the following expression [33-34], where is the liquid effective mass and is the spectral velocity for the liquid period . Notice that system does not include the mass of the tank.

(12)

To obtain the spectral velocity, an estimate of the fundamental vibration frequency is required. Graham and Rodríguez [12-13], as well as Chen et al. [6], give the following formula for the modal frequency ():

(13)

where for asymmetric modes, and for symmetric modes. The estimation of the fundamental vibration frequency in the Housner’s model is based on the values of and (Figure 1).

The effective mass can be estimated using a weight function similar to the function used for the horizontal velocity field

(14)

Computing the definite integrals and simplifying

(15)

If the total maximum kinetic energy (Eq. (11)) is set equal to the liquid input energy (Eq. (12)), an expression for can be obtained. This assumes that when the maximum kinetic energy occurs, the potential energy is equal to zero. Thus, the expression to estimate the maximum liquid sloshing height is

(16)

This value can be used to completely define both the displacement and the velocity fields.

2.3 Lateral hydrodynamic pressures

The lateral pressure on the wall tank can be obtained with the Bernoulli equation which, including the lateral ground acceleration and the hydrostatic pressure , results:

(17)

where is the velocity potential function, is the ground motion peak acceleration and is the gravity acceleration. This equation applies for inviscid, incompressible and irrotational fluids.

The pressure term can be obtained as follows. Taking the partial derivative of this term with respect to

Thus, the pressure associated to the velocity results:

The maximum vertical acceleration at the wall results (after Eq. (5)):

(18)

Since the lateral (relative) acceleration is equal to zero at the wall, the maximum amplitude of the wall pressure results (to evaluate the constant notice that at ):

(19)


As for the pressure term :

(20)

At the wall, the amplitude of this pressure second term is:

(21)

These two pressures ( and ) can be assumed as the “convective” pressure because both vary according to the liquid sloshing frequency. The pressure can be neglected [6] because its value is small, compared with the other terms.

The third pressure term (Eq. (17)) is related directly to the acceleration of the wall and it is identified as the impulsive pressure. Usually, this pressure has a larger magnitude than because in most cases its acceleration spectral ordinate is larger than the corresponding ordinate for the sloshing frequency. Since the tank wall is assumed rigid, the pressure computation with Eq. (17) would lead to a magnitude equal to (). In theory, the pressure would vary according to the ground shaking.

To be consistent with the estimation of pressures and , wherein an effective mass was considered, the same shape function used to compute is used here (Eq. (13)) to estimate . Thus, for , the shape function leads to the following pressure distribution (with a value of at the tank base and zero at the liquid free surface):

(22)

Finally, an estimation of the total hydrodynamic pressure on the wall (no including the hydrostatic one) can be obtained, by combining the pressures having different frequencies, using the square root of the sum of the squares (SRSS) rule. Thus:

(23)

As a summary of the proposed method, Figure 4 shows a diagram with the steps involved in the computation of both the liquid sloshing height and the total hydrodynamic pressures.

Draft De-la-Colina 143057818-image4.png
Figure 4. Steps to compute both the liquid sloshing height and the hydrodynamic pressures according to the proposed method

3. Numerical example

A numerical example is presented in this section to compare the solutions obtained with the following methodologies: a) ASCE Standard [1,3], b) Housner [4,5], and c) the method presented in this work. A computation using the CFE Code [2,37] is also included, although its formulas are similar to those obtained by Housner. These computations are compared with the FEM results published by Koh et al. [35,36].

The geometry of the tank containing water is defined with the following values: m ( m) and m. The system is excited with the NS component of the 1949 El Centro (Imperial Valley) earthquake ground motion (the perpendicular component is neglected). For comparison purposes, no load and resistance factors are included in the computations. No overstrength factors are used either. In all cases, wall pressures are computed for a unit width .

3.1 ASCE standard

Section 15.7 of the Standard (Tanks and Vessels) contains design recommendations for tanks supported at the base. According to this Standard [1], damping for sloshing (convective) effects shall be taken as 0.5% in the case of water. Since the impulsive effects are related to the mass rigidly attached to the tank, in this section the impulsive term is associated to the pressure in Eq. (17). Similarly, the convective effects are associated to the terms and of the same equation. No vertical forces associated to vertical ground accelerations are considered here.

According to the Standard, the natural period of the first (convective) mode of sloshing is (using as the diameter ' of the equation given by the Standard)

(24)

This formula uses English units, so , and : s.

The ACI 350.3 [3], which is also referred by the Standard, leads to the value of s, which is almost equal to the one obtained after using Eq. (13) [12,16].

As for the water sloshing maximum height, the Standard gives the following formula:

(25)

where is the Importance Factor and is the spectral acceleration of the sloshing liquid based on its vibration period and a damping factor . Considering = 5 s, the spectral ordinate is . Moreover, using , the sloshing height results equal to m. Equation (25) is practically the same as the one given by Chen et al. [6] for zero damping. Notice that the ACI-350.3 gives the following formula to estimate the maximum sloshing height

(26)

where the product between parenthesis can be seen as the spectral acceleration since is the zone peak ground acceleration and is the coefficient of spectral acceleration, which is dependent of the vibration period. The factor is the soil coefficient and is the importance factor taken equal to Thus, with = 0.075, the sloshing height results m.

For the computation of pressures and their resultants, the Standard recommends the use of the method given by the ACI 350.3 [3]. First, the lateral forces are computed. The impulsive force is simply evaluated as the product of the effective impulsive weight and the spectral acceleration (normalized with respect to ); i.e.,

(27)

The impulsive force is computed with . According to the ACI 350.3 the impulsive weight is , where is the total liquid weight, which for results kN = 180,000 kgf. Notice that the weight obtained with the effective mass given by Eq. (15) for the proposed method ( kN = 145,890 kgf) is about 80% of .

Therefore kN = 89,640 kgf and kN = 31,195 kgf.

Similarly, the convective force is given by (with kN = 93,976 kgf):

(28)

Considering = , (921.6 kN) = 69.1 kN = 7,048 kgf. According to the ACI 350.3, the pressures are obtained by applying the forces on each perpendicular wall with linear distributions (here is measured from the bottom up, m and m):

3.2 Housner

In this subsection, the wall pressures are computed taking into account Housner [4,5]. The impulsive pressure is computed with the following formula, where is measured from the liquid surface down (with and ):

(29)

The convective pressure is:

(30)

where and is an estimation of the maximum rotation of the liquid surface. To compute this value, an estimation of the sloshing height is required. Housner [5] gives the following equation to estimate it ( is the spectral displacement):

(31)

Thus, the value of can be computed as follows:

(32)

3.3 Method presented here

First, the maximum sloshing height is computed with Eq. (16). Using the spectral velocity m/s and with rad/s, the sloshing height results m. Then the pressures can be computed with Eqs. (19), (21) and (22). These pressures are combined with Eq. (23). The procedure follows the steps indicated in Figure 4.

3.4 CFE

The dynamic model as well as the formulas to estimate the sloshing height and the wall pressures are based on the Housner model. Therefore the estimation of is computed with Eq. (31), with . The formulas used to compute the pressures are (after some simplifications and with ):

(33)

and

(34)

where the coefficients and are the spectral accelerations computed for the vibrations periods of the impulsive and convective movements, respectively. The coefficients and are dimensionless values that describe the pressure variations in terms of the normalized height (). These graphs are similar to those included in Ref [36]. The CFE also recommends that the total pressure should be computed with the SRSS rule.

3.5 Comparisons

3.5.1 Sloshing heights

The liquid sloshing heights computed with each method are listed in Table 1. They vary between 51 and 75 cm. It can be observed that the smaller sloshing height is the one estimated with the finite element method [35] considering the wall thickness = 1.0 m (or rigid). Among the methods that assume the walls as rigid, the proposed method gives the nearest estimation to that computed with the FEM [35].

Table 1. Liquid sloshing maximum heights computed with several methods
Method D [m]
Housner 0.71
Standard ASCE 7-16 0.63
ACI-350.3 0.75
Method presented here 0.51
CFE-2015 0.71
Ko, Kim and Park ( m)* 0.70
Ko, Kim and Park ( m and rigid)* 0.30
is the thickness of the wall in the case of the study with flexible walls [35]

3.5.2 Convective pressures

To show a complete perspective of the computed pressures, the convective pressures are computed separately for those methods were these pressures are available. Figure 5 shows the convective pressures computed for some methods. The smaller convective pressures are estimated by the proposed method; however, this is not relevant because the design of tanks is carried out with the total pressures. The separation of convective and impulsive pressures is just a computational device.

Draft De-la-Colina 143057818-image5-c.png
Figure 5. Wall convective pressures computed with several methods

3.5.3 Impulsive pressures

Figure 6 shows the impulsive pressures computed for some methods. Contrary to the convective pressures, the larger convective pressures at the tank base are estimated by the proposed method.

Draft De-la-Colina 143057818-image6-c.png
Figure 6. Wall impulsive pressures computed with several methods

3.5.4 Total hydrodynamic pressures

As for the total pressures, the total wall pressures are shown in Figure 7. The pressures computed in Cho and Lee [29] are also included in the figure. These values were computed with the finite element method (FEM) and are assumed here as the “exact” pressures.

Draft De-la-Colina 143057818-image7-c.png
Figure 7. Total wall pressures computed with several methods


3.5.5 Sher forces and bending moments at the tank walls

For the wall design, an estimation of both the shear forces () and the bending moments () is required. An analysis of the walls can be carried out taking into account a theory of plates (either thin plate theory or thick plate theory). In the estimation of these forces () and the bending moments () a finite element analysis of the complete tank can also be considered, however given the accuracy involved in the estimations of pressures, this refinement is in many cases not justified. An isolated plate with adequate boundary conditions seems to be enough for the computation of forces. Since the length/height ratio of the tank of this example is larger than 2.0, a vertical strip of wall can be idealized as a contilever beam supported at the base with a width equal to 1.0 m. This simplification is used here as a simple way to compare these moments among the methods. In the case of reinforced-concrete tanks the bending moment referred here can be used to obtain the wall vertical reinforcement.

The distributions of shear forces per unit width are shown in Figure 8. It is clear that the distributions of these shear forces are similar among the methods. The shear forces computed with the proposed method resulted slightly larger than the finite element method (FEM) forces, given by Koh et al. [35]. The shear force at the wall base predicted by the proposed method resulted 13% larger than the value given by the FEM solution.

Draft De-la-Colina 143057818-image8-c.png
Figure 8. Shear forces per unit width of wall computed with several methods


The distributions of bending moments per unit width are shown in Figure 9. All distributions are similar among the methods. Again, the closer approximation to the finite element method (FEM) results [35], is the one obtained with the proposed method. The bending moment at the wall base predicted by the proposed method resulted only 6% larger than the value given by the FEM solution.

Draft De-la-Colina 143057818-image9-c.png
Figure 9. Bending moments per unit width of wall computed with several methods

4. Conclusions

A simple method to estimate both the liquid sloshing height and the wall pressures in tanks containing liquids is presented. The method is based on the Rayleigh-Ritz method applied to the liquid. To obtain these design parameters the total seismic input energy is made equal to the maximum total kinetic energy of the liquid for assumed liquid velocity fields. In the proposed method the tank is assumed rigid. Results indicate that the proposed method gives estimations of both the liquid sloshing height and the total hydrodynamic pressures similar to those obtained with both other simplified methodologies and using the finite element method.

The shear force and the bending moments computed with the proposed method resulted larger than the values computed with the solution obtained with the finite element method. For the example, the shear force at the wall base predicted by the proposed method resulted 13% larger than the value given by the FEM solution. As for the bending moment, the value at the wall base predicted by the proposed method resulted only 6% larger than the value given by the FEM solution. The proposed method seems to be simple enough that it can be used for design of rigid rectangular tanks. The methodology used for the proposed method can be extended to the study of cylindrical tanks. Moreover, the flexibility of the tank can be incorporated in the Rayleigh-Ritz solution proposing a displacement field for the walls and incorporating the corresponding strain energy. Additional examples with the proposed method are recommended before the method can be used extensively.

References

[1] American Society of Civil Engineers. ASCE/SEI 07-16. Minimum design loads and associated criteria for buildings and other structures. ASCE: Reston, Virginia, 2017.

[2] Comisión Federal de Electricidad. Manual de diseño de obras civiles – Diseño por sismo. CFE: Ciudad de Mexico, 2009. Spanish.

[3] American Concrete Institute. ACI 350.3-06: Seismic design of liquid-containing concrete structures and commentary ACI: Farmington Hills, 2006.

[4] Housner G.W. Dynamic pressures on accelerated fluid containers. Bull. Seismol. Soc. Am., 47:15-35, 1957.

[5] Housner G.W. The dynamic behavior of water tanks. Bull. Seismol. Soc. Am., 53:381-387, 1963.

[6] Chen W., Haroun M, Liu F. Large amplitude liquid sloshing in seismically excited tanks. Earthq. Eng. Struct. Dyn., 25:653-669, 1996.

[7] American Water Works Association. Welded carbon steel tanks for water storage. ANSI/AWWA D100-05 Standard. Denver, 2005.

[8] Veletsos A., Yang J. Earthquake response of liquid storage tanks. Proceedings 2nd Engineering Mechanics Specialty Conference, ASCE. Raleigh, (NC), 1977.

[9] Malhotra P.K., Wenk T., Wieland M. Simple procedure for seismic analysis of liquid-storage tanks. Struct. Eng. Int., 10(3):197-201, 2000.

[10] European Committee for Standarization (CEN). Eurocode 8. Design of Structures for Earthquake Resistance. Part 4: Silos, tanks and pipelines. CEN: Brussels, 2006.

[11] Epstein H. Seismic design of liquid-storage tanks. J. Struct. Div., 102:1659-1673, 1976.

[12] Graham E., Rodriguez A. The characteristics of fuel motion which affect airplane dynamics. Report SM 14212, Douglas Aircraft Company, Santa Monica (CA), 1951.

[13] Ibrahim R. Liquid sloshing dynamics: Theory and applications. New York (NY): Cambridge University Press, 2005.

[14] Langhaar H. Energy methods in applied mechanics. Krieger: Malabar (FL), 1962.

[15] Minowa C. Dynamic analysis for rectangular water tanks. Recent Adv. Lifeline Earthquake Engineering, Japan, 1980.

[16] Zhu F. Rayleigh-Ritz method in coupled fluid-structure interacting systems and its applications. J. Sound Vib., 186:543-550, 1995.

[17] Moradi R., Behnamfar F., Hashem S. Mechanical model for cylindrical flexible concrete tanks undergoing lateral excitation. Soil Dyn. Earthq. Eng., 106:148–162, 2018.

[18] Kim J.K., Koh H.M., Kwahk I.J. Dynamic response of rectangular flexible fluid containers. J. Eng. Mech., 122(9):807-817, 1996.

[19] Rashed A.A., Iwan W.D. Dynamic analysis of short-length gravity dams. J. Eng. Mech., 111(8):1067-1083, 1985.

[20] Zhao D., Hu Z., Chen G., Lim S., Wang S. Nonlinear sloshing in rectangular tanks under forced excitation. In.t J. Nav Arch. Ocean Eng., 10:545-565, 2018.

[21] Ning D.Z., Song W.H., Liu Y., Teng B. A boundary element investigation of liquid sloshing in coupled horizontal and vertical excitation. J. Appl. Math., 2012:1-20, 2012. DOI: 10.1155/2012/340640

[22] Hu Z., Zhang X., Li X., Li Y. On natural frequencies of liquid sloshing in 2-D tanks using boundary element method. Ocean. Eng., 153:88–103, 2018. https://doi.org/10.1016/j.oceaneng.2018.01.062.

[23] Hwang I.T., Ting K. Boundary element method for fluid-structure interaction problems in liquid storage tanks. J. Press. Vessel. Technol., 111(4):435-440, 1989. https://doi.org/10.1115/1.3265701.

[24] Taylor R.E., Wu G.X., Bai W., Hu Z.Z. Numerical wave tanks based on finite element and boundary element modeling. J. Offshore Mech. Arctic Eng., 130(3):031001, 2008.

[25] Wu G.X., Ma Q.W., Taylor R.E. Numerical simulation of sloshing waves in a 3D tank based on a finite element method. Appl. Ocean Res., 20:337–355, 1998.

[26] Aslam M. Finite element analysis of earthquake-induced sloshing in axisymmetric tanks. Int. J. Numer. Methods Eng., 17:159-170, 1981.

[27] Babu S.S., Bhattacharyya S. Finite element analysis of fluid-structure interaction effect on liquid retaining structures due to sloshing. Comput. Struc., 59(6):1165-1171, 1996.

[28] Arafa M. Finite element analysis of sloshing in rectangular liquid-filled tanks. J. Vib. Control, 13(7):883–903, 2007. DOI: 10.1177/1077546307078833.

[29] Cho J.R., Lee H.W. Non-linear finite element analysis of large amplitude sloshing flow in two-dimensional tank. Int. J. Numer. Methods Eng., 61(4):514–531, 2004. DOI: 10.1002/nme.1078.

[30] Hernández H., Hernández A., Valdés G. Non-linear sloshing effect on storage tanks subjected to high earthquake ground motion. Rev. Int. Métodos Numer. Calc. Diseño Ing., 31(3):198–206, 2015. Spanish. http://dx.doi.org/10.1016/j.rimni.2014.09.002.

[31] Frandsen J.B, Bortwick A.G. Simulation of sloshing motions in fixed and vertically excited containers using a 2-D inviscid -transformed finite difference solver. J. Fluids Struct., 18:197–214, 2003.

[32] Cook R.D., Malkus D.S., Plesha M.E., Witt R.J. Concepts and applications of the finite element analysis. 4th ed. John Wiley and Sons: New York (NY), 2002.

[33] Housner G.W. Limit design of structures to resist earthquakes. Proc First World Conference on Earthquake Engineering, Berkeley (CA), 1956.

[34] Uang C.M., Bertero V.V. Evaluation of seismic energy in structures. Earthq. Eng. Struct. Dyn., 19(1):77-90, 1990.

[35] Koh H.M., Kim J.K., Park J.H. Fluid—structure interaction analysis of 3-d rectangular tanks by a variationally coupled BEM-FEM and comparison with test results. Earthq. Eng. Struct. Dyn., 27(2):109-124, 1998.

[36] Dogangun A., Livaoglu R. Hydrodynamic pressures acting on the walls of rectangular fluid containers. Struct. Eng. Mech., 17(2):203-214, 2004.

[37] Flores C.B. Comportamiento mecánico de tanques atmosféricos de almacenamiento. Tesis de maestría. Escuela Superior de Ingeniería y Arquitectura (ESIA), Instituto Politécnico Nacional (IPN), Ciudad de México, 2009.
Back to Top

Document information

Published on 20/07/22
Accepted on 07/07/22
Submitted on 06/03/22

Volume 38, Issue 3, 2022
DOI: 10.23967/j.rimni.2022.07.001
Licence: CC BY-NC-SA license

Document Score

0

Views 55
Recommendations 0

Share this document

claim authorship

Are you one of the authors of this document?