(Created page with " == Abstract == This study evaluated the feasibility of transferring waste now stored in Tank SY-101 in the 200 West Area of the Hanford Site to a storage tank in 200 East Ar...")
 
m (Scipediacontent moved page Draft Content 586843758 to Cooley et al 2002a)
 
(No difference)

Latest revision as of 21:08, 25 January 2021

Abstract

This study evaluated the feasibility of transferring waste now stored in Tank SY-101 in the 200 West Area of the Hanford Site to a storage tank in 200 East Area through a 6.2-mile-long, 3-inch-diameter stainless steel pipeline. Using the Wasp slurry transport model, the critical velocity and expected pressure drop were calculated to determine 1) whether current SY-101 waste can be transferred through the existing cross-site transfer pipeline without additional dilution and, if it is not possible, how much dilution is needed.