(Created page with " == Abstract == This study evaluated the feasibility of transferring waste now stored in Tank SY-101 in the 200 West Area of the Hanford Site to a storage tank in 200 East Ar...") |
m (Scipediacontent moved page Draft Content 586843758 to Cooley et al 2002a) |
(No difference)
|
This study evaluated the feasibility of transferring waste now stored in Tank SY-101 in the 200 West Area of the Hanford Site to a storage tank in 200 East Area through a 6.2-mile-long, 3-inch-diameter stainless steel pipeline. Using the Wasp slurry transport model, the critical velocity and expected pressure drop were calculated to determine 1) whether current SY-101 waste can be transferred through the existing cross-site transfer pipeline without additional dilution and, if it is not possible, how much dilution is needed.
The different versions of the original document can be found in:
Published on 01/01/2002
Volume 2002, 2002
DOI: 10.2172/15001235
Licence: CC BY-NC-SA license
Are you one of the authors of this document?