Abstract

The conservation work carried out on the “Santa Maria degli Angeli” Orphanage in Castelgrande (Potenza, Italy) following the earthquakes of 1980 and 1981 is a good example of the need to evolve and refine the concept of seismic consolidation and upgrade of monumental heritage; this, considering not only the needs of the current structural calculation, but also those related to the design of durability and overall technological quality. Built from 1878 around the original nucleus of a chapel, the seminary, then an orphanage, kindergarten, nursery school, sewing workshop and school, and summer mountain colony, constitute a precise landmark in the landscape of the ancient town of Castelgrande. Severely damaged by the earthquakes, it was declared unfit for use and evicted, and is still abandoned today.Immediately afterwards, radical refurbishment works were carried out on it, with the creation of sub-foundations, injections and tackles with reinforced concrete slabs for the load-bearing walls, replacement of the floors in steel beams and bricks with reinforced concrete floors, replacement of the wooden roofs with others of the same configuration, but in steel beams and clay tables, with a reinforced concrete slab above. The workings were not completed due to lack of funds and those performed so far show today serious pathologies (in particular the corrosion of the reinforcement of the joist of the floors and of the steel beams) as result of the lack of attention to fundamentals of materials science and of durability. Based on the current legislation and calculation methods, the research verified the seismic vulnerability of the building and proposed the necessary corrective actions: in particular, the replacement of the roofs with others, lighter and more durable, made of laminated, conditioned local Quercus cerris wood. A new destination has been proposed, linked to the presence of the Astronomical Observatory, and its upgrade to nZEB has been designed, in respect of its monumental features.

Full document

The PDF file did not load properly or your web browser does not support viewing PDF files. Download directly to your device: Download PDF document

References

[1] Marconi, P. Il restauro e l’architetto. Teoria e pratica in due secoli di dibattito. Marsilio, Venezia (1988), ISBN 88-317-5759-8.

[2] Marconi, P. Materia e Significato. La questione del restauro architettonico. Gius. Laterza & Figli, Roma-Bari (1999), ISBN 88-420-5851-3.

[3] Marconi, P., Il recupero della bellezza. Skira, Milano (2005), ISBN 88-7624-484-0.

[4] Scappin, L. Il saper fare gli intonaci “par modo che li stiano bene”, dalle fonti scritte alle sperimentazioni. In F. Doglioni et al. (Eds.): Conoscenza e restauro degli intonaci e delle superfici murarie esterne di Venezia: campionature, esemplificazioni, indirizzi di intervento, Il Prato, Venezia (2017), pp. 374-423, ISBN-10 8863364036.

[5] AA.VV. Trattato sul consolidamento. Mancosu editore, Roma (2003), ISBN 88-87017-069.

[6] Giebeler, G., Krause, H. and Fisch, L. Refurbishment Manual. Maintenance, Conversions, Extensions. Basel Birkhäuser Architecture, Detail Construction Manuals, Munich Edition (2009), pp. 208-209 e 210-213.

[7] Lembo, F. Difendere e diffondere la cultura degli “strati di sacrificio” e del colore dell’edilizia storica. In: Convegno Architetti e Restauratori dei Beni Culturali, Trento, Italy, 7-8 novembre (2019, in press).

[8] Offenstein, F. Compatibles, incompatibles – ou comment associer les matériaux de construction, Editions du Moniteur, Paris (1988).

[9] CIB W 086 Publication 155, 1993. Building Pathology, A State-of-the-Art Report. Rotterdam, The Netherlands: CIB Press, 78 p.

[10] CIB W 086 Publication 393, 2013. A State-of-the-Art Report on Building Pathology. De Freitas V.P. (edited by). Rotterdam, The Netherlands: CIB Press, 200 p. ISBN 978-90- 6363-082-9.

[11] Lacasse, M.A. and Sjostrom, C. Methods for service life prediction of building materials and components – recent activities of the CIB W80/RILEM 187-SLM. In: Proceedings of the International Workshop on Management of Durability in the Building Process, Milan, Italy (2003), June 25-26, pp. 1-11.

[12] Lembo, F. and Marino, F.P.R. Il comportamento nel tempo degli edifici. Cause di degrado e soluzioni progettuali dei sistemi edilizi “tradizionali” ed “industrializzati”. Casi di studio. EPC Libri, Rome, Italy (2002), ISBN: 88-8184-241-6, con ampia bibliografia.

[13] Martone, A. Relazione al progetto di riparazione antisismica della Casa delle Figlie di Maria Ausiliatrice Salesiane di Don Bosco, Castelgrande (1986), presso l’Ufficio Tecnico del Comune di Castelgrande.

[14] D. Lgs. 22 gennaio 2004, n. 42 Codice dei beni culturali e del paesaggio, art. 29, 4° co. e D. M. 17 gennaio 2018 Aggiornamento delle “Norme tecniche per le costruzioni”. In: Supplemento ordinario alla Gazzetta Ufficiale n. 42 del 20 febbraio 2018, punto 8.4.2 “Intervento di miglioramento”, pag. 292.

[15] S.T.S. Software Tecnico Scientifico. CDMa Win: Computer Design of Masonries, software per la verifica di strutture in muratura. Siracusa, Italia (2018).

[16] F.P.R. Marino, F. Lembo, A. Videtta, C. La Notte. Quercus Cerris glued laminated timber: a novel material derived from wood. Tests on thermoigrometric conditioning, wood adhesives and flexion breakout tension. In: Sustainable Housing Design Emphasizing Urban Housing - XXXIV IAHS World Congress, Luciano Editore, Napoli, Italia (2006), Settembre 20-23. ISBN: 9788860260307. http://hdl.handle.net/11563/11205

[17] Lembo, F. and Marino F.P.R. Floors realized in Quercus Cerris laminated timber in buildings with structure in masonry, performing anti-seismic functions. In: B.P. Sinha and L. Tanaçan (Eds.): Proceedings of 8th International Seminar on Structural Masonry, Çizgi Basim Yayin Ltd. Sti, Istanbul, Turkey (2008), November 05-07, pp. 441-448. ISBN: 9789755613420. http://hdl.handle.net/11563/11203

[18] Lembo F, Marino FPR, Masullo R. Anti-seismic light, ductile, sustainable and reversible timber Quercus Cerris floors for reinforcement in conservation design. In: Branco JM, Poletti E, and Sousa HS (Eds.): Proceedings of 5th International Conference on Structural Health Assessment of Timber Structures - SHATiS’2019, Universidade do Minho, Escola de Engenharia, Guimarães, Portugal (2019), September 25-27, pp. 829-838. ISBN: 978- 989-54496-2-0. http://hdl.handle.net/11563/139675

[19] Petzel, M. and Heilmeyer, F. Reduce Reuse Recycle. Architecture as Resource. German Pavillion, Venice 13th International Architecture Exibition, Hatje Cantz (2012).

[20] Lembo, F. Isolare dall’esterno. Teoria, tecniche e manutenzione. Volume I Teoria. Edizioni C.E.L.I., Faenza, Italia (1990).

[21] Lembo, F. And Marino F.P.R. Ipotesi di ricostruzione del sistema delle coperture dell’anaktoron di Torre di Satriano. In: M. Osanna & M. Vullo (Eds.): Segni del potere - Oggetti di lusso dal Mediterraneo nell’Appennino lucano di età arcaica, Osanna Edizioni s.r.l., Venosa (PZ), Italia (2013) pp.75-82, ISBN: 9788881674015. http://hdl.handle.net/ 11563/61523

Back to Top
GET PDF

Document information

Published on 30/11/21
Submitted on 30/11/21

Volume Repair and strengthening strategies and techniques, 2021
DOI: 10.23967/sahc.2021.118
Licence: CC BY-NC-SA license

Document Score

0

Views 17
Recommendations 0

Share this document

claim authorship

Are you one of the authors of this document?