Published in ''Structural Health Monitoring'' Vol. 8 (3), pp. 195-205, 2009<br />
+
Published in ''Structural Health Monitoring'', Vol. 8 (3), pp. 195-205, 2009<br />
 
DOI: 10.1177/1475921708100779
 
DOI: 10.1177/1475921708100779
 +
 
== Abstract ==
 
== Abstract ==
  

Latest revision as of 13:39, 26 April 2019

Published in Structural Health Monitoring, Vol. 8 (3), pp. 195-205, 2009
DOI: 10.1177/1475921708100779

Abstract

In this paper, an experimental test performed on a hybrid steel plate girder was subjected to concentrated loads at the end of an unstiffened panel is presented. This load was intended to produce a typical reaction of the piers while launching steel girders in bridges. In this test, strain measurements were taken with conventional pre-wired gauges as well as with newly developed wirelessly connected strain-measuring system. Both measurements were carefully compared and the accuracy of the developed system was demonstrated. Results were also compared with numerical simulations deployed with FE models and on such a basis; the reliability of the developed wireless system was proven. Finally, suggestions of potential research trends in this area are provided.