<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
		<id>https://www.scipedia.com/wd/index.php?action=history&amp;feed=atom&amp;title=Sferruzza_Sabella_1994a</id>
		<title>Sferruzza Sabella 1994a - Revision history</title>
		<link rel="self" type="application/atom+xml" href="https://www.scipedia.com/wd/index.php?action=history&amp;feed=atom&amp;title=Sferruzza_Sabella_1994a"/>
		<link rel="alternate" type="text/html" href="https://www.scipedia.com/wd/index.php?title=Sferruzza_Sabella_1994a&amp;action=history"/>
		<updated>2026-04-06T18:24:00Z</updated>
		<subtitle>Revision history for this page on the wiki</subtitle>
		<generator>MediaWiki 1.27.0-wmf.10</generator>

	<entry>
		<id>https://www.scipedia.com/wd/index.php?title=Sferruzza_Sabella_1994a&amp;diff=208453&amp;oldid=prev</id>
		<title>Scipediacontent: Scipediacontent moved page Draft Content 581782523 to Sferruzza Sabella 1994a</title>
		<link rel="alternate" type="text/html" href="https://www.scipedia.com/wd/index.php?title=Sferruzza_Sabella_1994a&amp;diff=208453&amp;oldid=prev"/>
				<updated>2021-02-03T19:59:32Z</updated>
		
		<summary type="html">&lt;p&gt;Scipediacontent moved page &lt;a href=&quot;/public/Draft_Content_581782523&quot; class=&quot;mw-redirect&quot; title=&quot;Draft Content 581782523&quot;&gt;Draft Content 581782523&lt;/a&gt; to &lt;a href=&quot;/public/Sferruzza_Sabella_1994a&quot; title=&quot;Sferruzza Sabella 1994a&quot;&gt;Sferruzza Sabella 1994a&lt;/a&gt;&lt;/p&gt;
&lt;table class=&quot;diff diff-contentalign-left&quot; data-mw=&quot;interface&quot;&gt;
				&lt;tr style='vertical-align: top;' lang='en'&gt;
				&lt;td colspan='1' style=&quot;background-color: white; color:black; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan='1' style=&quot;background-color: white; color:black; text-align: center;&quot;&gt;Revision as of 19:59, 3 February 2021&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan='2' style='text-align: center;' lang='en'&gt;&lt;div class=&quot;mw-diff-empty&quot;&gt;(No difference)&lt;/div&gt;
&lt;/td&gt;&lt;/tr&gt;&lt;/table&gt;</summary>
		<author><name>Scipediacontent</name></author>	</entry>

	<entry>
		<id>https://www.scipedia.com/wd/index.php?title=Sferruzza_Sabella_1994a&amp;diff=208452&amp;oldid=prev</id>
		<title>Scipediacontent: Created page with &quot; == Abstract ==  The paper outlines the main features of the PGT 16 gas turbine with its auxiliaries and summarizes the experiences made in the field with the first seven unit...&quot;</title>
		<link rel="alternate" type="text/html" href="https://www.scipedia.com/wd/index.php?title=Sferruzza_Sabella_1994a&amp;diff=208452&amp;oldid=prev"/>
				<updated>2021-02-03T19:59:30Z</updated>
		
		<summary type="html">&lt;p&gt;Created page with &amp;quot; == Abstract ==  The paper outlines the main features of the PGT 16 gas turbine with its auxiliaries and summarizes the experiences made in the field with the first seven unit...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;&lt;br /&gt;
== Abstract ==&lt;br /&gt;
&lt;br /&gt;
The paper outlines the main features of the PGT 16 gas turbine with its auxiliaries and summarizes the experiences made in the field with the first seven units put in service starting in the first quarter of 1992.&amp;lt;/jats:p&amp;gt;                &amp;lt;jats:p&amp;gt;The PGT 16 gas turbine utilizes an aero-derivative gas generator, the LM 1600 manufactured by General Electric, coupled with a heavy-duty power turbine designed and manufactured by Nuovo Pignone. This power turbine is the same utilized for the 14000 HP heavy-duty gas turbine Nuovo Pignone PGT 10. The nominal shaft power is 18600 HP, with 36.4% efficiency.&amp;lt;/jats:p&amp;gt;                &amp;lt;jats:p&amp;gt;The design shaft speed of 7900 rpm makes this unit particularly suitable for mechanical drive applications, matching the typical speed range of centrifugal compressors in its power range. At the same time the high efficiency makes this unit attractive for both simple cycle and combined cycle power generation plants.&amp;lt;/jats:p&amp;gt;                &amp;lt;jats:p&amp;gt;The package design privileges maintenance requirements to minimize the downtime and to provide the highest possible degree of availability.&amp;lt;/jats:p&amp;gt;                &amp;lt;jats:p&amp;gt;The first 5 units in service have been installed along the Transcanada Pipeline and drive pipeline booster ‘compressors, PCL and BCL type: the other two units are in operation in a cogeneration facility in a paper-mill. At October ’93 the seven units have totalled 60,000 fired hours and the fleet leader 13,000 fired hours approximately.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
== Original document ==&lt;br /&gt;
&lt;br /&gt;
The different versions of the original document can be found in:&lt;br /&gt;
&lt;br /&gt;
* [http://proceedings.asmedigitalcollection.asme.org/data/conferences/asmep/82313/v003t07a013-94-gt-353.pdf http://proceedings.asmedigitalcollection.asme.org/data/conferences/asmep/82313/v003t07a013-94-gt-353.pdf]&lt;br /&gt;
&lt;br /&gt;
* [http://asmedigitalcollection.asme.org/GT/proceedings-pdf/doi/10.1115/94-GT-353/2404622/v003t07a013-94-gt-353.pdf http://asmedigitalcollection.asme.org/GT/proceedings-pdf/doi/10.1115/94-GT-353/2404622/v003t07a013-94-gt-353.pdf],&lt;br /&gt;
: [http://dx.doi.org/10.1115/94-gt-353 http://dx.doi.org/10.1115/94-gt-353]&lt;br /&gt;
&lt;br /&gt;
* [https://asmedigitalcollection.asme.org/GT/proceedings/GT1994/78859/V003T07A013/236239 https://asmedigitalcollection.asme.org/GT/proceedings/GT1994/78859/V003T07A013/236239],&lt;br /&gt;
: [http://proceedings.asmedigitalcollection.asme.org/proceeding.aspx?articleid=2144046 http://proceedings.asmedigitalcollection.asme.org/proceeding.aspx?articleid=2144046],&lt;br /&gt;
: [https://academic.microsoft.com/#/detail/2320625916 https://academic.microsoft.com/#/detail/2320625916]&lt;/div&gt;</summary>
		<author><name>Scipediacontent</name></author>	</entry>

	</feed>