<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
		<id>https://www.scipedia.com/wd/index.php?action=history&amp;feed=atom&amp;title=He_et_al_2018a</id>
		<title>He et al 2018a - Revision history</title>
		<link rel="self" type="application/atom+xml" href="https://www.scipedia.com/wd/index.php?action=history&amp;feed=atom&amp;title=He_et_al_2018a"/>
		<link rel="alternate" type="text/html" href="https://www.scipedia.com/wd/index.php?title=He_et_al_2018a&amp;action=history"/>
		<updated>2026-05-08T11:14:28Z</updated>
		<subtitle>Revision history for this page on the wiki</subtitle>
		<generator>MediaWiki 1.27.0-wmf.10</generator>

	<entry>
		<id>https://www.scipedia.com/wd/index.php?title=He_et_al_2018a&amp;diff=201032&amp;oldid=prev</id>
		<title>Scipediacontent: Scipediacontent moved page Draft Content 972620235 to He et al 2018a</title>
		<link rel="alternate" type="text/html" href="https://www.scipedia.com/wd/index.php?title=He_et_al_2018a&amp;diff=201032&amp;oldid=prev"/>
				<updated>2021-02-02T02:44:54Z</updated>
		
		<summary type="html">&lt;p&gt;Scipediacontent moved page &lt;a href=&quot;/public/Draft_Content_972620235&quot; class=&quot;mw-redirect&quot; title=&quot;Draft Content 972620235&quot;&gt;Draft Content 972620235&lt;/a&gt; to &lt;a href=&quot;/public/He_et_al_2018a&quot; title=&quot;He et al 2018a&quot;&gt;He et al 2018a&lt;/a&gt;&lt;/p&gt;
&lt;table class=&quot;diff diff-contentalign-left&quot; data-mw=&quot;interface&quot;&gt;
				&lt;tr style='vertical-align: top;' lang='en'&gt;
				&lt;td colspan='1' style=&quot;background-color: white; color:black; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan='1' style=&quot;background-color: white; color:black; text-align: center;&quot;&gt;Revision as of 02:44, 2 February 2021&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan='2' style='text-align: center;' lang='en'&gt;&lt;div class=&quot;mw-diff-empty&quot;&gt;(No difference)&lt;/div&gt;
&lt;/td&gt;&lt;/tr&gt;&lt;/table&gt;</summary>
		<author><name>Scipediacontent</name></author>	</entry>

	<entry>
		<id>https://www.scipedia.com/wd/index.php?title=He_et_al_2018a&amp;diff=201031&amp;oldid=prev</id>
		<title>Scipediacontent: Created page with &quot; == Abstract ==  Within the framework of SENSKIN EU project (grant No. 635844), we have developed a soft capacitive sensor using silicone dielectric elastomer for Structural h...&quot;</title>
		<link rel="alternate" type="text/html" href="https://www.scipedia.com/wd/index.php?title=He_et_al_2018a&amp;diff=201031&amp;oldid=prev"/>
				<updated>2021-02-02T02:44:50Z</updated>
		
		<summary type="html">&lt;p&gt;Created page with &amp;quot; == Abstract ==  Within the framework of SENSKIN EU project (grant No. 635844), we have developed a soft capacitive sensor using silicone dielectric elastomer for Structural h...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;&lt;br /&gt;
== Abstract ==&lt;br /&gt;
&lt;br /&gt;
Within the framework of SENSKIN EU project (grant No. 635844), we have developed a soft capacitive sensor using silicone dielectric elastomer for Structural health monitoring (SHM). This sensor has a thin layer of stretchable silicone dielectric film and soft silicone electrodes as the active layer, which transduces strain signal into the easy-monitored capacitance change. The sensor output is measured as a ration of the sensor’s capacitance to the known value of the reference capacitor. The capacitive output of the sensor showed a linear response upon stretching in the strain range of 4.5 % to 5.5% with a pre-strain of 5.0 %. The sensor output increased by 0.01 when the strain was increased by 1.0 %. The sensor was exposed to a temperature change from -35 oC to 55 oC (the supposed working temperature range) with a ramping of 0.2 oC/min and, as a result, it showed a linear temperature dependence behavior with a slope of -0.001 sensor output per oC. Therefore, with the help of the embedded Platinum-1000 temperature sensor, the thermal expansion effect on the capacitive output can be excluded from the actual strain-induced capacitance change. These results provide practical reference to the application of the silicon-elastomer sensor for the SHM systems.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
== Original document ==&lt;br /&gt;
&lt;br /&gt;
The different versions of the original document can be found in:&lt;br /&gt;
&lt;br /&gt;
* [https://figshare.com/articles/Senskin_deformable_silicone-elastomer_sensors_for_structural_health_monitoring_assessment_of_strain_sensitivity_and_correction_for_thermal_expansion/8033516 https://figshare.com/articles/Senskin_deformable_silicone-elastomer_sensors_for_structural_health_monitoring_assessment_of_strain_sensitivity_and_correction_for_thermal_expansion/8033516]&lt;br /&gt;
&lt;br /&gt;
* [https://zenodo.org/record/2649097 https://zenodo.org/record/2649097] under the license http://creativecommons.org/licenses/by/4.0/legalcode&lt;br /&gt;
&lt;br /&gt;
* [https://zenodo.org/record/2649097 https://zenodo.org/record/2649097],&lt;br /&gt;
: [http://dx.doi.org/10.5281/zenodo.2649096 http://dx.doi.org/10.5281/zenodo.2649096] under the license http://creativecommons.org/licenses/by/4.0/legalcode&lt;br /&gt;
&lt;br /&gt;
* [https://zenodo.org/record/2649097 https://zenodo.org/record/2649097],&lt;br /&gt;
: [http://dx.doi.org/10.5281/zenodo.2649097 http://dx.doi.org/10.5281/zenodo.2649097] under the license http://creativecommons.org/licenses/by/4.0/legalcode&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
DOIS: 10.5281/zenodo.2649097 10.5281/zenodo.2649096&lt;/div&gt;</summary>
		<author><name>Scipediacontent</name></author>	</entry>

	</feed>