Abstract
The effect of waterproof membrane and steel reinforcement protection on the concrete bridge deck is modeled. The attention is paid to the durability prediction related to steel reinforcement corrosion initiation based on the chloride penetration. Thus 2-D finite element chloride [...]
Abstract
This examined the performance of the iron-foil sensor in concrete and its relationship with the amount of chloride in the solution simulating concrete. The corrosion sensor reacted at a chloride ion concentration of 500 ppm. From the results, it was inferred that the sensor has a [...]Abstract
Reinforced concrete structures are commonly used in civil engineering. However, the number of deteriorations in these structures is increasing, especially problems related to steel corrosion. Also, according studies, corrosion is responsible for about 3.5 % of annual GDP with recovery [...]Abstract
The new generation of structural Eurocodes will include climate change adaption measures in order to enhance the climate resilience of infrastructures across Europe. This paper discusses the impact that climate change might have on reinforced concrete structures subjected to corrosion, [...]
Abstract
Pipelines present a unique challenge to monitoring because of the great geographical distances they cover, their burial depth, their age, and the need to keep the product flowing without much interruption. Most other engineering structures that require monitoring do not pose such [...]
Abstract
This report details the testing equipment, procedures and results performed under Task 7.2 Sealing Simulated Leaks. In terms of our ability to seal leaks identified in the technical topical report, Analysis of Current Field Data, we were 100% successful. In regards to maintaining [...]Abstract
Results of two studies conducted as part of the Strategic Petroleum Reserve (SPR) Pipeline Corrosion Control Program are reported. These studies focused on evaluation of rotary-applied concrete materials for internal pipeline protection against the erosive and corrosive effects of [...]Abstract
Centrifugally-cast concrete liners applied to the interiors of plain steel pipe sections were tested for corrosion performance in brine solutions. An American Petroleum Institute (API) standard concrete, with and without additions of a styrene-butadiene copolymer latex, was subjected [...]Abstract
The two broad categories of fiber-reinforced composite liner repair and deposited weld metal repair technologies were reviewed and evaluated for potential application for internal repair of gas transmission pipelines. Both are used to some extent for other applications and could be [...]